8. System Specifications
This chapter provides basic operational and environmental specifications for the hardware in this guide. If you have any questions regarding the specifications outlined here, contact your sales representative, call VDURA Technical Support at 1-888-726-2727, or visit the VDURA support site at support.VDURA.com.
This chapter contains the following sections:
- V5000 Director Node Server Specifications
- V5000 Storage Node Server Specifications
- V5000 4U78 JBOD Specifications
- V5000 4U108 JBOD Specifications
8.1 V5000 Director Node Server Specifications
Physical Specifications
| W x D x H | 17.5 x 33 x 1.75 in. - 1 rack unit 445 x 838 x 44 mm |
|---|---|
| Net weight, enclosure plus drives | 41 lbs. 18.6 kg |
Environmental Specifications
| Operating temperature | 0-35°C |
|---|---|
| Non-operating temperature | -10-60°C |
| Operating humidity | N/A |
| Non-operating humidity | 5-95% non-condensing |
Power Specifications
| Power supply output rating | 1300 W |
|---|---|
| Input line current | 6.25 A @ 208 VAC 50-60 Hz |
| Power consumption* | 776 W @ 208 VAC (typical) 1201 W @ 208 VAC (maximum) |
| Operating current* | 3.73 A @ 208 VAC (typical) 5.77 A @ 208 VAC (maximum) |
| BTU rating* | 2647 BTU/hr @ 208 VAC (typical) 4097 BTU/hr @ 208 VAC (maximum) |
- Values derived from example systems in use under normal load. Your actual results may vary based on configuration and load.
8.2 V5000 Storage Node Server Specifications
Physical Specifications
| W x D x H | 17.5 x 33 x 1.75 in. - 1 rack unit 445 x 838 x 44 mm |
|---|---|
| Net weight, enclosure plus drives | 38.8 lbs. 17.6 kg |
Environmental Specifications
| Operating temperature | 0-35°C |
|---|---|
| Non-operating temperature | -10-60°C |
| Operating humidity | N/A |
| Non-operating humidity | 5-95% non-condensing |
Power Specifications
| Power supply output rating | 1300 W |
|---|---|
| Input line current | 6.25 A @ 208 VAC 50-60 Hz |
| Power consumption* | 722 W @ 208 VAC (typical) 1138 W @ 208 VAC (maximum) |
| Operating current* | 3.47 A @ 208 VAC (typical) 5.47 A @ 208 VAC (maximum) |
| BTU rating* | 2463 BTU/hr @ 208 VAC (typical) 3882 BTU/hr @ 208 VAC (maximum) |
- Values derived from example systems in use under normal load. Your actual results may vary based on configuration and load.
8.3 V5000 4U78 JBOD Specifications
Physical Specifications
| W x D x H (without CMA) | 17.5 x 31.9 x 7 in. 434 x 811 x 176 mm |
|---|---|
| W x D x H (with CMA) | 17 x 38.4 x 7 in. 434 x 975 x 176 mm |
| Weight without drives | 94 lbs. 42.6 kg |
| Weight with drives | 207.2 lbs. 94.5 kg |
Environmental Specifications
| Operating temperature | 0-35°C |
|---|---|
| Non-operating temperature | -20-60°C |
| Operating humidity | 20-80% |
| Non-operating humidity | 10-90% |
Power Specifications
| Power supply output rating | 1600 W |
|---|---|
| Input line current | 7.69 A @ 208 VAC 50-60 Hz |
| Power consumption* | 839 W @ 208 VAC (typical) 1155 W @ 208 VAC (maximum) |
| Operating current* | 4.03 A @ 208 VAC (typical) 5.55 A @ 208 VAC (maximum) |
| BTU rating* | 2862 BTU/hr @ 208 VAC (typical) 3940 BTU/hr @ 208 VAC (maximum) |
- Values derived from example systems in use under normal load. Your actual results may vary based on configuration and load.
8.4 V5000 4U108 JBOD Specifications
Physical Specifications
| W x D x H (without CMA) | 17 x 41 x 7 in. 434 x 1050 x 176 mm |
|---|---|
| W x D x H (with CMA) | 17 x 50 x 7 in. 434 x 1273 x 176 mm |
| Weight without drives | 105 lbs. 47.6 kg |
| Weight with drives | 263.2 lbs. 119.4 kg |
Environmental Specifications
| Operating temperature | 0-35°C |
|---|---|
| Non-operating temperature | -20-60°C |
| Operating humidity | 20-80% |
| Non-operating humidity | 10-90% |
Power Specifications
| Power supply output rating | 2000 W |
|---|---|
| Input line current | 9.62 A @ 208 VAC 50-60 Hz |
| Power consumption* | 1081 W @ 208 VAC (typical) 1448 W @ 208 VAC (maximum) |
| Operating current* | 5.20 A @ 208 VAC (typical) 6.96 A @ 208 VAC (maximum) |
| BTU rating* | 3688 BTU/hr @ 208 VAC (typical) 4940 BTU/hr @ 208 VAC (maximum) |
- Values derived from example systems in use under normal load. Your actual results may vary based on configuration and load.