17. VDURA System Error Messages
This chapter provides a numerical list of VDURA system error messages.
Error messages are categorized as follows:
| Category | Description |
|---|---|
| Info | Error recovery messages or configuration changes are typically logged to the Events page (see 5.2 Events Panel). |
| Warning | Developing problems that might impair system availability or data integrity are logged to the Events page and emailed to system administrators. |
| Critical | Problems that are an imminent risk to system availability or data integrity are logged to the Events page and emailed to system administrators. |
The following table lists error messages and PanActive Manager error handling. %%SERIAL%%, %%SHELFID%%, and similar tokens are placeholders filled in with the actual serial number, shelf ID, or other identifying value at runtime.
| Error Code | Category | Error Description | Recommended Action |
|---|---|---|---|
| 8405 | Warning | Power supply 1 failed: Power supply 1 has failed (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. | Contact VDURA Technical Support. |
| 8406 | Warning | Power supply 1 unsupported version: Power supply 1 is an unsupported version (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. | Contact VDURA Technical Support. |
| 8407 | Critical | Incompatible Power Supplies: Power supplies in shelf are incompatible (shelf serial %%SHELFID%%). This configuration is not supported. | Contact VDURA Technical Support. |
| 8408 | Warning | Power supply 1 not found: Power supply 1 is missing (shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. | Check if power supply 1 is inserted properly. |
| 8409 | Critical | Power supply 1 over maximum temperature: Power supply 1 temperature is above threshold (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. | Ambient temperature is too high. Adjust room temperature. |
| 8410 | Warning | Power supply 1 temperature high: Power supply 1 exceeds optimal temperature (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8411 | Info | Power supply 1 under temperature: Power supply 1 is under optimal temperature (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too low. Adjust room temperature. |
| 8412 | Warning | Power supply 1, AC power fail: AC power disconnected from power supply 1 (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. | Check that power supply is plugged in. |
| 8413 | Warning | Power supply 1 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 8414 | Warning | A 950W power supply was replaced with an 800W power supply in PS1 (shelf serial %%SHELFID%%). This scenario can cause damage to the 800W power supply. | Insert a 950W power supply into this location. |
| 8415 | Warning | Power supply 2 failed: Power supply 2 has failed (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. | Contact VDURA Technical Support. |
| 8416 | Warning | Power supply 2 unsupported version: Power supply 2 is an unsupported version (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. | Contact VDURA Technical Support. |
| 8417 | Warning | Node disk 9 encountered disk errors. | Contact VDURA Technical Support. |
| 8418 | Warning | Power supply 2 not found: Power supply 2 is missing (shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. | Check if power supply 2 is inserted properly. |
| 8419 | Critical | Power supply 2 over maximum temperature: Power supply 2 temperature is above threshold (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8420 | Warning | Power supply 2 temperature high: Power supply 2 exceeds optimal temperature (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8421 | Info | Power supply 2 temperature high: Power supply 2 exceeds optimal temperature (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient Temperature is too low. Adjust room temperature. |
| 8422 | Warning | Power supply 2, AC power fail: AC power disconnected from power supply 2 (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. | Check that power supply is plugged in. |
| 8423 | Warning | Power supply 2 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 8424 | Warning | A 950W power supply was replaced with an 800W power supply in PS2 (shelf serial %%SHELFID%%). This scenario can cause damage to the 800W power supply. | Insert a 950 W power supply into this location. |
| 8425 | Critical | Battery temperature over maximum: Shelf battery temperature is above critical threshold (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8426 | Critical | Battery failed: Shelf battery has failed (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8427 | Warning | Battery unsupported version: Shelf battery is an unsupported version (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8428 | Warning | Battery failure predicted: Shelf battery is predicted to fail (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8429 | Critical | Battery not found: Shelf battery is missing (shelf serial %%SHELFID%%). | Check if battery module is inserted properly. |
| 8430 | Warning | Battery temperature high: Shelf battery exceeds optimal temperature (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8431 | Warning | Battery low: Shelf battery charge is low (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Wait until fully charged. It can take up to 6 hours to fully charge battery. If the problem persists, contact VDURA Technical Support for further assistance regarding this message. |
| 8432 | Info | Battery under temperature: Shelf battery is under optimal temperature (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too low. Adjust room temperature. |
| 8433 | Warning | Node disk 10 encountered disk errors, contact VDURA Technical Support. | Contact VDURA Technical Support. |
| 8434 | Warning | Enclosure over power budget: The power draw of nodes exceeds the power supply capacity. | Contact VDURA Technical Support for steps to bring the shelf within power budget. |
| 8435 | Critical | Net Module 1 failed: Net Module 1 has failed (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8436 | Warning | Net Module 1 unsupported version: Net Module 1 is an unsupported version (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8437 | Warning | Node disk 11 encountered disk errors, contact VDURA Technical Support. | Contact VDURA Technical Support. |
| 8438 | Critical | Net Module 1 not found: Net Module 1 is missing (shelf serial %%SHELFID%%). | Check if switch 1 is inserted properly. |
| 8439 | Warning | Node disk 12 encountered disk errors, contact VDURA Technical Support. | Contact VDURA Technical Support. |
| 8440 | Warning | Net Module 1 checksum error: Checksum error on Device U6 (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8441 | Warning | Net Module 1 checksum error: Checksum error on Device U8 (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8442 | Warning | Node disk 13 encountered disk errors. | Contact VDURA Technical Support. |
| 8443 | Critical | Net Module 1 over maximum temperature: Switch 1 temperature is above threshold (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8444 | Warning | Net Module 1 temperature high: Net Module 1 exceeds optimal temperature (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8445 | Info | Net Module 1 is under optimal temperature (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Ambient temperature is too low. Adjust room temperature. |
| 8446 | Warning | Net Module 1 is resetting (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch management interface did not respond. Please wait 90 seconds for reset to complete. |
| 8447 | Warning | Management interface of Net Module 1 is not responding (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch management interface is not responding. Please reset the switch when system is not busy and check that the switch firmware is up-to-date. |
| 8448 | Warning | Net Module 1 firmware is out of date (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch firmware is out of date; upgrade is recommended. Contact VDURA Technical Support for further assistance. |
| 8449 | Warning | Net Module 1 firmware is unsupported (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch firmware is not supported. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance. |
| 8450 | Critical | Node is unavailable: Node is unavailable due to a software failure. Administrative action may be needed to reconstruct this node. | Contact VDURA Technical Support to repair this node. If the node cannot be repaired, go to the Node Detail page and use the Reconstruct control to start reconstruction of data. |
| 8451 | Critical | Node exceeds maximum temperature: Node temperature exceeds threshold. Shutdown is imminent. | Adjust room temperature and check fans. |
| 8452 | Critical | Node shutdown: Node has shutdown automatically due to critically high temperature. | Adjust room temperature and check fans. |
| 8453 | Critical | AC power failed: Shelf %%SHELFID%% is running on backup battery power. Shutdown is imminent. | Go to the Hardware page and click the System Shutdown button. |
| 8454 | Warning | Node disk nearly full: Node’s disk space that is available for user data has reached %%PERCENTFULL%%% of capacity. | Add more storage to the StorageSet. |
| 8455 | Critical | Node disk full: Node’s disk space that is available for user data has reached 100% of capacity. | Add more storage to the StorageSet. |
| 8456 | Warning | Node temperature high: Node exceeds optimal operating temperature. | Ambient temperature is too high. Adjust room temperature. |
| 8457 | Warning | Node memory errors: Number of memory errors in node are abnormally high. | Contact VDURA Technical Support for a replacement node. |
| 8458 | Warning | Node is now offline. | |
| 8459 | Warning | Node needs to be reinitialized: Node has unknown data on it and must be reinitialized to be used in this system. | Contact VDURA Technical Support. |
| 8460 | Warning | Node is unavailable. | Node may be rebooting. Check for any network problems and be sure that the node is properly inserted in the slot. |
| 8461 | Warning | OSD out of service: Reconstruction will begin on the volumes in the StorageSet. | Wait until reconstruction completes on all volumes in the StorageSet and then replace the OSD. |
| 8462 | Warning | No compatibility info for Net Module 1 firmware (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | There is no compatibility info for the switch firmware. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance. |
| 8463 | Critical | Net Module 1 firmware is incompatible (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Upgrade switch firmware to a supported version. Contact VDURA Technical Support for further assistance. |
| 8464 | Warning | Node disk 14 encountered disk errors, contact VDURA Technical Support. | Contact VDURA Technical Support. |
| 8465 | Info | Node removed: Node has been removed from the system. | No specific user action is required. |
| 8466 | Info | Node under temperature: Node is under optimal operating temperature. | Ambient temperature is too low. Adjust room temperature. |
| 8467 | Info | Node discovered by the system. | No specific user action is required. |
| 8468 | Info | Node is now online. | No specific user action is required. |
| 8469 | Info | Node has been moved from its previous enclosure and/or slot location. | No specific user action is required. |
| 8470 | Info | Node needs upgrade: Node software is inconsistent with system software. | The system will automatically attempt to apply its software to this node. No action is needed. |
| 8471 | Info | Node is performing a fsck. | Wait until fsck completes. |
| 8472 | Warning | Node unsupported version: Node hardware is not supported by current version of software (hardware serial %%BLADESERIAL%%, shelf serial %%SHELFID%%, slot %%SLOTID%%). | Check that the hardware serial on this node is valid. |
| 8473 | Warning | Node filesystem nearly full: The local filesystem %%FILESYSTEM%% on this node is %%PERCENTFULL%%% full. | |
| 8474 | Info | Node filesystem no longer full: The filesystem %%FILESYSTEM%% on node is %%PERCENTFULL%%% full. There is enough space now. | No specific user action is required. |
| 8475 | Info | Node disk no longer full: Node’s disk space that is available for user data has reached %%PERCENTFULL%%% of capacity. There is enough space now. | No specific user action is required. |
| 8476 | Warning | Node disk 9 SMART predicted failure. | Contact VDURA Technical Support. |
| 8477 | Warning | Node disk 10 SMART predicted failure. | Contact VDURA Technical Support. |
| 8480 | Critical | Node disk 0 encountered disk errors. | Contact VDURA Technical Support. |
| 8481 | Warning | Node disk 0 SMART predicted failure. | Contact VDURA Technical Support. |
| 8482 | Warning | Node disk 0 is an unsupported version. | Contact VDURA Technical Support. |
| 8483 | Warning | Node disk 0 is missing from the node. | Contact VDURA Technical Support. |
| 8484 | Info | Node disk 0 is rebuilding to mirror disk 1. | No action is needed. |
| 8485 | Warning | Net Module 1 firmware needs upgrade but upgrade firmware file not available (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch firmware is not supported. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance. |
| 8486 | Warning | Net Module 1 firmware is newer than tested version (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Contact VDURA Technical Support to obtain the firmware file and for further assistance. |
| 8487 | Warning | Net Module 1 detected uplink on a port that should not be an uplink (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Check that the enclosure switch is cabled correctly. Uplink should be sfp6, cx4, or lagg of ge. |
| 8488 | Warning | Net Module 1 is not using trigger logic - potential performance problem (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | If the warning persists, contact VDURA Technical Support. |
| 8489 | Info | Net Module 1 is experiencing packet flooding - performance may be reduced (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | No specific user action is required. |
| 8490 | Critical | Node disk 1 encountered disk errors. | Contact VDURA Technical Support. |
| 8491 | Warning | Node disk 1 SMART predicted failure. | Contact VDURA Technical Support. |
| 8492 | Warning | Node disk 1 is an unsupported version. | Contact VDURA Technical Support. |
| 8493 | Warning | Node disk 1 is missing from the node. | Contact VDURA Technical Support. |
| 8494 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8495 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8496 | Info | Node disk 1 is rebuilding to mirror disk 0. | No specific user action is required. |
| 8497 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8498 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8499 | Warning | Node disk 12 SMART predicted failure. | Contact VDURA Technical Support. |
| 8500 | Warning | Node disk 13 SMART predicted failure. | Contact VDURA Technical Support. |
| 8501 | Info | Storage added to StorageSet %%SETNAME%%. | No specific user action is required. |
| 8502 | Info | StorageSet affinity changed for shelf %%SHELFID%%. | No specific user action is required. |
| 8503 | Critical | StorageSet full: StorageSet %%SETNAME%% is at 100 % capacity, further writes or snapshots may not be allowed. | Add more storage to the StorageSet. |
| 8504 | Warning | Node disk 14 SMART predicted failure. | Contact VDURA Technical Support. |
| 8505 | Warning | Node disk 9 is an unsupported version. | Contact VDURA Technical Support. |
| 8506 | Warning | OSDs are not online in StorageSet %%SETNAME%%. See node and volume status for more details. | Check node and volume status. |
| 8507 | Warning | Node disk 10 is an unsupported version. | Contact VDURA Technical Support. |
| 8508 | Warning | StorageSet nearly full: %%PERCENTFULL%%% of space available to user in StorageSet %%SETNAME%% is full. | Add more storage to the StorageSet. |
| 8509 | Critical | StorageSet has no spare space: Reconstruction cannot be started on StorageSet %%SETNAME%% as there are no reserved OSDs in it. Add more storage to the StorageSet as soon as possible. | Add more storage to the StorageSet. |
| 8510 | Info | StorageSet created: StorageSet %%SETNAME%% is created. | No specific user action is required. |
| 8511 | Info | StorageSet deleted: StorageSet %%SETNAME%% is deleted. | No specific user action is required. |
| 8513 | Info | StorageSet capacity imbalance detected: The distribution of used space on OSDs in StorageSet %%SETNAME%% is not balanced. The system is working to rebalance the StorageSet automatically. | Turn on capacity balancing for this StorageSet. If capacity balancing is already turned on, the system will automatically balance the distribution of used space in this StorageSet. |
| 8515 | Warning | OSDv4 block allocation policy configuration is not consistent for all nodes in StorageSet %%SETNAME%% | |
| 8516 | Warning | StorageSet %%SETNAME%% uses OSDv4 block allocation policy that will be deprecated in the future releases | |
| 8517 | Warning | Node disk 11 is an unsupported version. | Contact VDURA Technical Support. |
| 8518 | Warning | Node disk 12 is an unsupported version. | Contact VDURA Technical Support. |
| 8519 | Warning | Node disk 13 is an unsupported version. | Contact VDURA Technical Support. |
| 8520 | Warning | Node disk 14 is an unsupported version. | Contact VDURA Technical Support. |
| 8521 | Warning | Volume degraded: One OSD is not responding. Performance on volume %%VOLNAME%% is degraded. | Minimize accessing this volume for reads and writes. The performance of the system will be slower than expected. Reconstruction of data will start soon. |
| 8522 | Warning | Volume offline: Volume %%VOLNAME%% has been taken offline-unavailable for administrative purpose. | |
| 8523 | Critical | Volume down: Volume %%VOLNAME%% is not accessible. | |
| 8524 | Info | Volume online: Volume %%VOLNAME%% has been brought online. | No specific user action is required. |
| 8525 | Info | Volume created: Volume %%VOLNAME%% has been created. | No specific user action is required. |
| 8526 | Info | Volume deleted: Volume %%VOLNAME%% has been deleted. | No specific user action is required. |
| 8527 | Warning | Volume has damaged files: Volume %%VOLNAME%% has damaged files. | Contact VDURA Technical Support. |
| 8528 | Warning | Volume offline: Volume %%VOLNAME%% has been taken offline for administrative purpose. | |
| 8529 | Warning | Inconsistent parity equation: Object %%OBJID%% (offset %%OFFSET%%, length %%LENGTH%%) has an inconsistent parity equation among its component objects.%%REPORTED_BY%%%%TRANSIENT% % | Contact VDURA Technical Support. |
| 8531 | Info | Volume %%VOLNAME%% has been set read- only. | No specific user action is required. |
| 8532 | Warning | Node disk 9 is missing from the node. | Contact VDURA Technical Support. |
| 8533 | Info | Volume background cleanup started: Background cleanup on the volume %%VOLNAME%% has begun. | No specific user action is required. |
| 8534 | Info | Volume background cleanup stopped: Background cleanup on the volume %%VOLNAME%% has stopped. | No specific user action is required. |
| 8535 | Critical | File System Recovery start: File System Recovery (FSRC) on the volume %%VOLNAME%% has begun. | The system is checking and repairing the volume. During this process, the volume is offline. |
| 8536 | Warning | File System Recovery recommended: File System Recovery (FSRC) recommended to repair inconsistencies in volume %%VOLNAME%%. | The system has discovered an unexpected file system inconsistency. To repair inconsistencies, click the volume name, then start FSRC using the Recover Volume control. The volume will be offline while FSRC repairs it. Note that depending on the size of the volume, FSRC may take several hours to complete. Until the volume is repaired, some files or directories may be inaccessible. |
| 8537 | Info | File System Recovery end: File System Recovery (FSRC) on the volume %%VOLNAME%% has completed. Fixed %%FIXED%% objects during recovery. | The system has finished checking and repairing the volume. To examine any damaged files, click the volume name and follow the link to Damaged Files in Volume. |
| 8538 | Info | Volume background cleanup completed: Background cleanup on the volume %%VOLNAME%% has completed. Reconstructed %%RECONED%% objects, removed %%REMOVED%% stale components. | No specific user action is required. |
| 8539 | Critical | Volume fault-tolerance exceeded: Volume %%VOLNAME%% has too many failed OSDs. | |
| 8540 | Critical | File System Recovery failed: File System Recovery (FSRC) on the volume %%VOLNAME%% failed to recover volume. Fixed %%FIXED%% objects, found %%FENCED%% damaged objects, and deleted %%DELETED%% objects during recovery. | An error occurred while checking and repairing the volume. The system is unable to bring the volume online. To start FSRC again, click the volume name, then click the Recover Volume control. If FSRC is unable to complete, contact VDURA Technical Support for assistance. |
| 8541 | Critical | File System Recovery failed: File System Recovery (FSRC) on the volume %%VOLNAME%% failed to recover volume. | One or more data fragments have been removed from file system but are still occupying space in the system. Contact VDURA Technical Support for assistance to recover them. |
| 8542 | Info | Volume reconstruction for drain: The system has started reconstructing data in volume %%VOLNAME%% to complete the drain process. | Wait until volume comes back online. |
| 8543 | Info | Volume rescue completed: Volume rescue on the volume %%VOLNAME%% has completed. Fixed %%FIXED%% objects, and deleted %%DELETED%% objects during rescue. | The system has finished rescuing the volume. Run PanCLI volume rescue report in service mode to download a detailed report. |
| 8544 | Warning | Node disk 10 is missing from the node. | Contact VDURA Technical Support. |
| 8545 | Warning | Node disk 11 is missing from the node. | Contact VDURA Technical Support. |
| 8546 | Warning | Node disk 12 is missing from the node. | Contact VDURA Technical Support. |
| 8547 | Warning | Node disk 13 is missing from the node. | Contact VDURA Technical Support. |
| 8548 | Warning | Node disk 14 is missing from the node. | Contact VDURA Technical Support. |
| 8549 | Info | Volume reconstruction stop: reconstruction of data in volume %%VOLNAME%% has stopped due to configuration or state changes. | Check node and volume status for more details. |
| 8550 | Warning | StorageSet has no spare space: StorageSet %%SETNAME%% has requested %%NUMDESIRED%% spare storage nodes but currently has no spares. This will not have any effect upon reconstruction of data that may be in progress, but the system will not be able to reconstruct or drain any additional storage nodes until another storage node is added. | Add more storage to the StorageSet. |
| 8551 | Critical | StorageSet spare failure: StorageSet %%SETNAME%% does not have enough space to reserve space for reconstruction. Requested %%NUMDESIRED%% MB but only reserved %%NUMRESERVED%% MB. | |
| 8552 | Warning | Volume reconstruction began: Reconstruction of data in volume %%VOLNAME%% began. | Wait until reconstruction completes. |
| 8553 | Critical | Reconstruction failed: Encountered error during reconstruction of data in volume %%VOLNAME%%. | Contact VDURA Technical Support. |
| 8554 | Info | Volume reconstruction complete: Reconstruction of data in volume %%VOLNAME%% is complete. | No specific user action is required. |
| 8555 | Info | StorageSet spare success: Successfully reserved requested space of %%NUMDESIRED%% MB in StorageSet %%SETNAME%%. | No specific user action is required. |
| 8556 | Critical | Volume reconstruction failed: some objects could not be reconstructed. | Contact VDURA Technical Support. |
| 8557 | Critical | Reconstruction failed: There was not enough space or not enough storage nodes to complete reconstruction in volume %%VOLNAME%%. Add more storage to the StorageSet. | Add more storage to the StorageSet. |
| 8558 | Info | StorageSet spare success: StorageSet %%SETNAME%% contains %%NUMDESIRED%% spare storage nodes for reconstruction. | No specific user action is required. |
| 8559 | Critical | Volume rescue reconstruction began: rescue reconstruction of data in volume %%VOLNAME%% began. | Wait until rescue reconstruction completes. |
| 8560 | Critical | Hard Quota Violation: Hard quota limit reached on volume %%VOLNAME%%. No further writes allowed in this volume. | Try one or more of the following: • Increase hard quota for the volume. • Delete unneeded files from the volume. Note that in an environment with snapshots, deleting files may not actually free space. • Delete the oldest snapshot and verify that enough space is available from the Storage tab. • Add more storage to the StorageSet. |
| 8561 | Warning | Soft Quota Violation: Soft quota limit reached on volume %%VOLNAME%%. | Try one or more of the following: • Increase soft quota for the volume. • Delete unneeded files from the volume. Note that in an environment with snapshots, deleting files may not actually free space. • Delete the oldest snapshot and verify that enough space is available from the Storage tab. • Add more storage to the StorageSet. |
| 8564 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8566 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8567 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8568 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8571 | Warning | Software - Unexpected result: System software encountered unexpected behavior in module %%CODEMODULE%%: %%MESSAGE%%. (version %%VERSION%%, %%FILENAME%%:%%LINENUMBER%%) | |
| 8572 | Info | Software Process Failed: The process %%MODULENAME%% has failed with exit code %%EXITCODE%% and will be restarted. | The system has restarted this application automatically, so no action is needed. If you see many such messages, please report a bug with VDURA Technical Support. |
| 8573 | Info | Software Process Restarts: The process %%MODULENAME%% exited with status %%EXITCODE%% and will be restarted. | The system has restarted this application automatically, so no action is needed. If you see many such messages, please report a bug with VDURA Technical Support. |
| 8574 | Info | DHCP Leases Low: A node failed to join the system as there are no IP Addresses available. Increase the range of IP Addresses. | Add more IP addresses to address range. Go to the Network page and select the IP Ranges page to make changes. |
| 8575 | Info | System online: The system is now online. | No specific user action is required. |
| 8576 | Info | System going offline-unavailable: The system is being brought offline. Data services will be turned off. | No specific user action is required. |
| 8577 | Warning | System offline-unavailable: Data services off. | |
| 8578 | Info | System rebooting: System is preparing for a reboot. | No specific user action is required. |
| 8579 | Info | System power down: System is powering down due to a failed node. | No specific user action is required. |
| 8580 | Warning | System is locked for new nodes: A new node was not allowed to join the system as the system is locked. | To let the node join, go to the Hardware page and unlock the system. If the new node is intended for a different system on this subnet, no action is required. |
| 8581 | Warning | IP address %%IP%% appears to be in use by a machine that is not part of this storage cluster. | To fix this problem, either edit the system IP ranges not to include any IPs that are taken by machines outside of your system or change the outside machine to use an IP address that is outside of the system’s reserved IP ranges. |
| 8582 | Warning | DirectFlow Client with IP Address %%IPADDR%% clock skew of %%CLOCKSKEW%% seconds exceeds %%MAXCLOCKSKEW%% second limit | |
| 8583 | Warning | System reboot failed. | |
| 8584 | Warning | System power down failed. | |
| 8585 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8586 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8587 | Info | Generic informational message. | This is an informational message. No action is needed. |
| 8588 | Warning | Node has a warning condition the cause of which is either a kernel crash or unknown. | No specific user action is required. Contact VDURA Technical Support if the event reported causes any malfunction. |
| 8589 | Critical | Node is in error condition the cause of which is unknown. | No specific user action is required. Contact VDURA Technical Support if the event reported causes any malfunction. |
| 8590 | Info | Syslog warning: slow syncs seen by iopathv4 | No specific user action is required. |
| 8591 | Info | If the drift increases to 10,000 milliseconds, DirectFlow clients will degrade to read-only mode. | This is an informational message. However, it does suggest that the node generating the message is having problems contacting time servers or with its clock. |
| 8592 | Warning | This will cause DirectFlow clients to degrade to read-only mode. | Clock drift can be caused by loss of contact with your external time sources. |
| 8593 | Info | If the drift increases to 10,000 milliseconds, it may cause volumes on the StorageSet that this node is a part of to become inaccessible. | Clock drift can be caused by loss of contact with your external time sources. |
| 8594 | Warning | This will cause volumes on the StorageSet that this node is a part of to become temporarily inaccessible. | Clock drift can be caused by loss of contact with the realm president or local hardware or software failures. |
| 8595 | Info | ntpd monitor: Clock skew from time server %%IP%% of %%NUMMS%% milliseconds has dropped below the threshold of %%NUMMSTHRESHOLD%% milliseconds. | No action is needed. The time skew between the external time source and the node is improving. |
| 8596 | Warning | If this continues, DirectFlow clients will degrade to read-only mode. | Entering local clock sync can be caused by loss of contact with the time servers configured. You can use tools like ntptrace and ping to diagnose and rectify them. |
| 8597 | Warning | If this situation persists, this node’s clock may drift from the clocks on the system, this node may go offline. Please check to see that this node re-synchronizes within the hour. | Nodes going into local time sync like this can be caused by loss of contact with the realm president or local hardware or software failures. |
| 8598 | Info | This event relates to being in local sync. | No action is needed. Whatever caused nodes to move to local sync has been rectified. |
| 8599 | Info | Timeout after 1 hour+10 min, as syslog_watcher will wait for 1 hour before sending a repeat message. | Collect the /var/log/ security file from this host to check the origin of failed login attempts. |
| 8602 | Warning | Failed to send email via SMTP server %%SMTPSERVER%% to %%EMAILADDRESSES%% with subject %%SUBJECT%%: %%MESSAGE%%. | Check the connectivity to SMTP server as well as SMTP server security settings. |
| 8603 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8604 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8605 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8606 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8607 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8608 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8609 | Info | Node disk 9 is rebuilding to mirror disk 1. | No specific user action is required. |
| 8610 | Info | Node disk 10 is rebuilding to mirror disk 1. | No specific user action is required. |
| 8612 | Info | Node disk 11 is rebuilding to mirror disk 1. | No specific user action is required. |
| 8613 | Info | Node disk 12 is rebuilding to mirror disk 1. | No specific user action is required. |
| 8614 | Info | Node disk 13 is rebuilding to mirror disk 1. | No specific user action is required. |
| 8615 | Info | Node disk 14 is rebuilding to mirror disk 1. | No specific user action is required. |
| 8620 | Info | Upgrading message. | No specific user action is required. |
| 8621 | Info | Upgrading message. | No specific user action is required. |
| 8622 | Info | Upgrading message. | No specific user action is required. |
| 8623 | Info | Upgrading message. | No specific user action is required. |
| 8624 | Info | Upgrading message. | No specific user action is required. |
| 8625 | Critical | Upgrading message. | |
| 8626 | Info | Upgrading message. | No specific user action is required. |
| 8627 | Critical | Upgrading message. | |
| 8628 | Critical | Upgrading message. | |
| 8629 | Critical | Upgrading message. | |
| 8630 | Critical | Upgrading message. | |
| 8631 | Critical | Upgrading message. | |
| 8632 | Critical | Upgrading message. | |
| 8633 | Info | Upgrading message. | No specific user action is required. |
| 8634 | Critical | Upgrading message. | |
| 8635 | Warning | Upgrading message. | |
| 8636 | Info | Upgrading message. | No specific user action is required. |
| 8637 | Info | Upgrading message | No specific user action is required. |
| 8638 | Info | Upgrading message. | No specific user action is required. |
| 8639 | Info | Upgrading message. | No specific user action is required. |
| 8640 | Info | Upgrading message. | No specific user action is required. |
| 8641 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8642 | Critical | Node disk %%DRIVENUMBER%% encountered disk errors. | Contact VDURA Technical Support. |
| 8643 | Warning | Node disk %%DRIVENUMBER%% SMART predicted failure. | Contact VDURA Technical Support. |
| 8644 | Warning | Node disk %%DRIVENUMBER%% is missing from the node. | Contact VDURA Technical Support. |
| 8645 | Warning | Node disk %%DRIVENUMBER%% is an unsupported version. | Contact VDURA Technical Support. |
| 8646 | Info | Node disk %%DRIVENUMBER%% is rebuilding to mirror disk 1. | No specific user action is required. |
| 8647 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 8650 | Info | System is coming up. | Wait a few minutes. |
| 8651 | Info | Initial system startup has completed. | Check the health of the system. |
| 8652 | Info | Volume service moved: Service %%SERVICEID%% moved from Director %%FROMHWSERIAL%% to Director %%TOHWSERIAL%%. | No specific user action is required. |
| 8653 | Warning | Volume service moved leaving no backup: Service %%SERVICEID%% moved from Director %%FROMHWSERIAL%% to Director %%TOHWSERIAL%%. | To ensure the volume service gets a backup location, make sure all directors are online. |
| 8654 | Info | Volume service backup enabled: Service %%SERVICEID%% now has backup Director %%TOHWSERIAL%%. | No specific user action is required. |
| 8655 | Warning | Volume service backup disabled: Service %%SERVICEID%% does not have a backup. | To ensure the volume service gets a backup location, make sure all directors are online. |
| 8656 | Info | System going offline: The system is being brought offline. Data services will be turned off. | No specific user action is required. |
| 8657 | Warning | System offline: Data services off. | |
| 8658 | Info | System going offline for upgrade: The system is being brought offline for upgrade. Data services will be turned off. | No specific user action is required. |
| 8659 | Warning | System offline for upgrade: Data services off. | |
| 8661 | Info | Alias %%IP_ALIAS%% has been assigned. | No specific user action is required. |
| 8662 | Warning | Alias %%IP_ALIAS%% cannot be assigned: %%MESSAGE%% | Check the status of all directors and validate IP alias configuration. |
| 8663 | Info | Volume service removed: Service %%SERVICEID%% manages no volumes and has been removed. | No specific user action is required. |
| 8664 | Warning | Detected too many recent login failures. Check event log for details about failures on individual hosts. | Collect the /var/log/ security file from affected hosts to check the origin of failed login attempts. |
| 8665 | Warning | Detected one or more AWOL clients. Check event log for client details. | Check the health of the clients reported as AWOL. |
| 8670 | Warning | This battery module is nearing the end of its useful 3.5 year life. | The battery module can continue to be used but should be replaced as soon as reasonably possible. Please open a Service Request with a list of battery hardware serial numbers impacted. The VDURA battery module is a consumable item but may be covered under the service entitlement you have purchased for this enclosure. |
| 8684 | Critical | Node’s Small File Filesystem has reached 90% or more of capacity. | Delete data or add additional storage. |
| 8685 | Warning | Node’s Small File Filesystem capacity is more than 80% full. | Delete data or add additional storage. |
| 8686 | Info | Node’s Small File Filesystem has reached 50% or more of capacity. | No specific user action is required. |
| 8687 | Info | Node’s Small File Filesystem is below 50% capacity. | No specific user action is required. |
| 8688 | Critical | Node’s Large File Filesystem has reached 90% or more of capacity. | Delete data or add additional storage. |
| 8689 | Warning | Node’s Large File Filesystem capacity is more than 80% full. | Delete data or add additional storage. |
| 8690 | Info | Node’s Large File Filesystem has reached 50% or more of capacity. | No specific user action is required. |
| 8691 | Info | Node’s Large File Filesystem is below 50% capacity. | No specific user action is required. |
| 8697 | Critical | Node’s Metadata Filesystem has reached 90% or more of capacity. | Contact VDURA Technical Support. |
| 8698 | Warning | Node’s Metadata Filesystem capacity is more than 70% full. | Contact VDURA Technical Support. |
| 8699 | Info | Node’s Metadata Filesystem has reached below 70% of capacity. | No specific user action is required. |
| 8800 | Critical | JBOD (JBOD serial number: %%SERIAL%%) failed | Contact VDURA Technical Support. |
| 8801 | Critical | JBOD (JBOD serial number: %%SERIAL%%) not found. | Contact VDURA Technical Support. |
| 8802 | Warning | JBOD %%SERIAL%% predicted failure. | Contact VDURA Technical Support. |
| 8803 | Critical | IO module %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed. | Contact VDURA Technical Support. |
| 8804 | Critical | IO module %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) not found. | Contact VDURA Technical Support. |
| 8805 | Warning | IO module %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) predicted failure. | Contact VDURA Technical Support. |
| 8806 | Critical | JBOD fan %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed. | Contact VDURA Technical Support. |
| 8807 | Critical | JBOD fan %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) not found. | Contact VDURA Technical Support. |
| 8808 | Warning | JBOD fan %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) predicted failure. | Contact VDURA Technical Support. |
| 8809 | Critical | JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed. | Contact VDURA Technical Support. |
| 8810 | Critical | JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) not found. | Contact VDURA Technical Support. |
| 8811 | Warning | JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) predicted failure. | Contact VDURA Technical Support. |
| 8812 | Warning | JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed during the monthly battery test. | Contact VDURA Technical Support. |
| 8813 | Warning | JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) AC power fail. | Contact VDURA Technical Support. |
| 8900 | Warning | Power supply 1 fan failed: Enclosure fan has failed in power supply 1 (fan serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. | Contact VDURA Technical Support. |
| 8901 | Warning | Battery fan failed: Enclosure fan has failed in battery module (fan serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8902 | Warning | Power supply 2 fan failed: Enclosure fan has failed in power supply 2 (fan serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. | Contact VDURA Technical Support. |
| 8903 | Critical | There are 2 or more fans failed or missing in the enclosure. System will shut down automatically in a few minutes if this condition is not cleared up. | Contact VDURA Technical Support. |
| 8950 | Critical | Net module 2 has failed (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8951 | Warning | Net Module 2 unsupported version (switch 2 serial, enclosure serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8952 | Critical | Net module 2 not found (enclosure serial %%SHELFID%%). | Check if switch 2 is inserted properly. |
| 8953 | Critical | Net module 2 over maximum temperature (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8954 | Warning | Net Module 2 exceeds optimal temperature (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Ambient temperature is too high. Adjust room temperature. |
| 8955 | Info | Net Module 2 under optimal temperature (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Ambient temperature is too low. Adjust room temperature. |
| 8956 | Warning | Net Module 2 checksum error: Checksum error on Device U6 (switch 2 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8957 | Warning | Net Module 2 checksum error: Checksum error on Device U8 (switch 2 serial %%SERIAL%%, shelf serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8958 | Warning | Net Module 2 is resetting (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch management interface did not respond. Please wait 90 seconds for reset to complete. |
| 8959 | Warning | Management interface of Net Module 2 is not responding (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch management interface is not responding. Please reset the switch when system is not busy and check that the switch firmware is up-to-date. |
| 8960 | Warning | Net Module 2 firmware is out of date (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch firmware is out of date; upgrade is recommended. Contact VDURA Technical Support for further assistance. |
| 8961 | Warning | Net Module 2 firmware is unsupported (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Switch firmware is not supported. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance. |
| 8962 | Warning | No compatibility info for Net Module 2 firmware (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | There is no compatibility info for the switch firmware. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance. |
| 8963 | Critical | Net module 2 firmware is incompatible (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Upgrade switch firmware to a supported version. Contact VDURA Technical Support for further assistance. |
| 8964 | Warning | Net Module 2 firmware needs upgrade but upgrade firmware file not available (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Contact VDURA Technical Support. |
| 8965 | Warning | Net Module 2 firmware is newer than tested version (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Consider downgrading switch firmware to a supported version. Contact VDURA Technical Support for further assistance. |
| 8966 | Warning | Net Module 2 detected uplink on a port that should not be an uplink (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | Check that the enclosure switch is cabled correctly. Uplink should be sfp6, cx4, or lagg of ge. |
| 8968 | Info | Net Module 2 is experiencing packet flooding - performance may be reduced (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). | If the warning persists, contact VDURA Technical Support. |
| 8975 | Info | Battery test started. Any change in LED pattern on this shelf can be safely ignored during the test. The test will take up to one minute (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | No specific user action is required. |
| 8976 | Info | Battery test completed successfully (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | No specific user action is required. |
| 8977 | Critical | Battery test failed: battery drained too quickly (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | |
| 8978 | Info | Transient error during Battery test: battery test aborted (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). | Battery test will automatically run again later. |
| 9050 | Warning | Node low battery: Node is waiting for shelf battery to get charged. | |
| 9051 | Info | Node online fsck active: Online fsck is running on the node. | No specific user action is required. |
| 9052 | Info | Node online fsck inactive: Online fsck stopped running on the node. | No specific user action is required. |
| 9053 | Info | Node got address: Node assigned IP Address by the system. | No specific user action is required. |
| 9062 | Info | Node clock sync: Node is performing NTP clock synchronization. | Wait up to 2 minutes for clock synchronization to complete. If clock synchronization lasts longer than 2 minutes, make sure at least one of the NTP servers is responding. |
| 9063 | Warning | One or more of this node’s drives have failed. | Contact VDURA Technical Support. |
| 9064 | Warning | One or more of this node’s drives may be damaged. | Contact VDURA Technical Support. |
| 9065 | Info | The quality of this node’s drives cannot be determined at this time. The system will continue testing the drives until a determination can be made. | No action is needed. |
| 9066 | Info | Tests for this node’s drives have passed. | No specific user action is required. |
| 9067 | Info | Node not ready to serve data: No active object storage service. | No specific user action is required. |
| 9068 | Info | Hardware activated. | No specific user action is required. |
| 9069 | Info | Performing secure erase. | No specific user action is required. |
| 9070 | Info | Hardware is booting. | No specific user action is required. |
| 9071 | Info | Hardware is shutting down. | No specific user action is required. |
| 9072 | Info | Timeout after 1 hour+10 min, as syslog_watcher will wait for 1 hour before sending a repeat message. | Check the health of this client. |
| 9073 | Warning | Found %%NUMECC%% ECC errors in the past %%TIMEPERIOD%%. | Node may need to be drained or replaced depending on severity of ECC correctable error rate. |
| 9074 | Warning | Found %%NUMERR%% %%ERRTYPE%% errors on drive %%DRIVENAME%%. | Node may need to be drained or replaced depending on severity of ATA sector error rate. |
| 9075 | Warning | Node is degraded: Controller is reconstructing this OSD. | Contact VDURA Technical Support. |
| 9079 | Warning | %%NUMERR%% IPS communication timeout errors occurred to OSD %%IP%% in the past %%TIMEPERIOD%%. | Collect logs for the OSD and contact VDURA Technical Support. |
| 9080 | Info | Hardware deactivated | No specific user action is required. |
| 9081 | Info | Node not ready to serve data: Network error. | No specific user action is required. |
| 9082 | Info | Node not ready to serve data: Polling/DB state is not reconciled. | No specific user action is required. |
| 9083 | Info | Node not ready to serve data: Configuration is not valid. | No specific user action is required. |
| 9100 | Info | OSD has successfully drained. | |
| 9101 | Info | OSD drain status: %%BYTES_REMAINING%% bytes (in %%OBJECTS_REMAINING%% objects) out of %%TOTAL_BYTES%% (and %%TOTAL_OBJECTS%% objects) still need to be drained. | Check the drain status on the OSD Detail page to see whether drain is blocked. |
| 9102 | Warning | Configuration message. | Correct the NIS configuration. |
| 9103 | Info | Configuration message. | No specific user action is required. |
| 9104 | Warning | Configuration message. | Make sure the NIS servers is responding. |
| 9105 | Info | Configuration message. | No specific user action is required. |
| 9120 | Warning | Lost connection to LDAP service could not be reestablished. | Check the LDAP server connectivity. To retry, disable and re- enable LDAP. Also make sure that LDAP is in the Name Resolution Order list. |
| 9122 | Warning | Connection to LDAP service reestablished. | |
| 9126 | Warning | Lost connection to NIS service could not be reestablished. | Check the NIS server connectivity. To retry, disable and re- enable NIS User/Group Name Resolution. Also make sure that NIS is in the Name Resolution Order list. |
| 9127 | Warning | Connection to NIS service reestablished. | |
| 9150 | Info | User Quota Violation Hard (bytes): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. No further writes allowed for this %%QUOTATYPE%% in this volume unless it has at most %%QUOTATHRSHLD%% of data. | Increase hard quota bytes limit. Delete unneeded files from volume to keep usage below limit. |
| 9151 | Info | User Quota Violation Soft (bytes): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. | Increase soft quota bytes limit. Delete unneeded files from volume to keep usage below limit. |
| 9152 | Info | User Quota Violation Hard (files): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. No further file creates allowed for this %%QUOTATYPE%% in this volume. | Increase hard quota file limit. Delete unneeded files from volume to keep usage below limit. |
| 9153 | Info | User Quota Violation Soft (files): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. | Increase soft quota file limit. Delete unneeded files from volume to keep usage below limit. |
| 9170 | Info | User quota usage calculation in progress for volume %%VOLNAME%%. Quota usage data may not be current. | |
| 9171 | Info | User quota usage calculation is pending for volume %%VOLNAME%%. Quota usage data may not be current. | No specific user action is required. |
| 9172 | Info | User quota usage calculation completed for volume %%VOLNAME%%. | No specific user action is required. |
| 9182 | Warning | Node NIC 1 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9183 | Warning | Node NIC 2 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9184 | Warning | Node NIC 3 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9185 | Warning | Node NIC 4 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9186 | Warning | Node NIC 5 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9187 | Warning | Node NIC 6 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9188 | Warning | Node NIC 7 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9189 | Warning | Node NIC 8 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9190 | Warning | Node NIC 9 failed: %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 9202 | Warning | Node NIC 1 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9203 | Warning | Node NIC 2 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9204 | Warning | Node NIC 3 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9205 | Warning | Node NIC 4 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9206 | Warning | Node NIC 5 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9207 | Warning | Node NIC 6 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9208 | Warning | Node NIC 7 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9209 | Warning | Node NIC 8 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9210 | Warning | Node NIC 9 transmission error: %%DESCRIPTION%% | Check cabling. |
| 9222 | Warning | Node NIC 1 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9223 | Warning | Node NIC 2 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9224 | Warning | Node NIC 3 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9225 | Warning | Node NIC 4 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9226 | Warning | Node NIC 5 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9227 | Warning | Node NIC 6 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9228 | Warning | Node NIC 7 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9229 | Warning | Node NIC 8 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9230 | Warning | Node NIC 9 slow transmission: %%DESCRIPTION%% | Check 10 GE switch configuration. |
| 9242 | Warning | Node NIC 1 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9243 | Warning | Node NIC 2 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9244 | Warning | Node NIC 3 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9245 | Warning | Node NIC 4 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9246 | Warning | Node NIC 5 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9247 | Warning | Node NIC 6 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9248 | Warning | Node NIC 7 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9249 | Warning | Node NIC 8 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9250 | Warning | Node NIC 9 not full duplex: %%DESCRIPTION%% | Check switch configuration. |
| 9262 | Warning | Node NIC 1 not active: %%DESCRIPTION%% | Check cabling. |
| 9263 | Warning | Node NIC 2 not active: %%DESCRIPTION%% | Check cabling. |
| 9264 | Warning | Node NIC 3 not active: %%DESCRIPTION%% | Check cabling. |
| 9265 | Warning | Node NIC 4 not active: %%DESCRIPTION%% | Check cabling. |
| 9266 | Warning | Node NIC 5 not active: %%DESCRIPTION%% | Check cabling. |
| 9267 | Warning | Node NIC 6 not active: %%DESCRIPTION%% | Check cabling. |
| 9268 | Warning | Node NIC 7 not active: %%DESCRIPTION%% | Check cabling. |
| 9269 | Warning | Node NIC 8 not active: %%DESCRIPTION%% | Check cabling. |
| 9270 | Warning | Node NIC 9 not active: %%DESCRIPTION%% | Check cabling. |
| 9282 | Critical | Node NIC 1 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9283 | Critical | Node NIC 2 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9284 | Critical | Node NIC 3 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9285 | Critical | Node NIC 4 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9286 | Critical | Node NIC 5 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9287 | Critical | Node NIC 6 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9288 | Critical | Node NIC 7 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9289 | Critical | Node NIC 8 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9290 | Critical | Node NIC 9 wrong broadcast address: %%DESCRIPTION%% | Configure the broadcast address correctly. |
| 9302 | Warning | Node NIC 1 not active: %%DESCRIPTION%% | Try rebooting the node. |
| 9303 | Warning | Node NIC 2 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9304 | Warning | Node NIC 3 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9305 | Warning | Node NIC 4 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9306 | Warning | Node NIC 5 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9307 | Warning | Node NIC 6 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9308 | Warning | Node NIC 7 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9309 | Warning | Node NIC 8 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9310 | Warning | Node NIC 9 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9322 | Warning | Node NIC 1 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9323 | Warning | Node NIC 2 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9324 | Warning | Node NIC 3 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9325 | Warning | Node NIC 4 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9326 | Warning | Node NIC 5 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9327 | Warning | Node NIC 6 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9328 | Warning | Node NIC 7 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9329 | Warning | Node NIC 8 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9330 | Warning | Node NIC 9 has no external connectivity: %%DESCRIPTION%% | Check cable and switch configuration. |
| 9362 | Warning | Node NIC 1 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9363 | Warning | Node NIC 2 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9364 | Warning | Node NIC 3 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9365 | Warning | Node NIC 4 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9366 | Warning | Node NIC 5 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9367 | Warning | Node NIC 6 not in use: %%DESCRIPTION%% | Try rebooting the node. |
| 9368 | Warning | Node NIC 7 LACP not active: %%DESCRIPTION%% | Check switch configuration. |
| 9369 | Warning | Node NIC 8 LACP not active: %%DESCRIPTION%% | Check switch configuration. |
| 9370 | Warning | Node NIC 9 LACP not active: %%DESCRIPTION%% | Check switch configuration. |
| 9400 | Warning | Power supply 1 failed. | Contact VDURA Technical Support. |
| 9401 | Warning | Power supply 1 has unsupported version. | Contact VDURA Technical Support. |
| 9402 | Warning | Power supply 1 not found. | Check whether power supply 1 is inserted properly. |
| 9403 | Warning | Power supply 1 failure predicted. | Contact VDURA Technical Support. |
| 9404 | Warning | Power supply 1 AC power fail: AC power disconnected from power supply 1. | Check that power supply 1 is plugged in. |
| 9410 | Warning | Power supply 2 failed. | Contact VDURA Technical Support. |
| 9411 | Warning | Power supply 2 has unsupported version. | Contact VDURA Technical Support. |
| 9412 | Warning | Power supply 2 not found. | Check whether power supply 2 is inserted properly. |
| 9413 | Warning | Power supply 2 failure predicted. | Contact VDURA Technical Support. |
| 9414 | Warning | Power supply 2 AC power fail: AC power disconnected from power supply 2. | Check that power supply 2 is plugged in. |
| 9420 | Warning | IPMI card failed. | Contact VDURA Technical Support. |
| 9421 | Warning | IPMI card not responding correctly. | Contact VDURA Technical Support. |
| 9422 | Warning | IPMI card not found. | Check whether IPMI card is inserted properly. |
| 9423 | Warning | Non-volatile memory system failure is predicted. | Contact VDURA Technical Support. |
| 9424 | Warning | Non-volatile memory system has failed. | Contact VDURA Technical Support. |
| 9430 | Warning | Fan 1 failed. | Contact VDURA Technical Support. |
| 9431 | Warning | Fan 1 speed too slow. | Contact VDURA Technical Support. |
| 9435 | Warning | Fan 2 failed. | Contact VDURA Technical Support. |
| 9436 | Warning | Fan 2 speed too slow. | Contact VDURA Technical Support. |
| 9440 | Warning | Fan 3 failed. | Contact VDURA Technical Support. |
| 9441 | Warning | Fan 3 speed too slow. | Contact VDURA Technical Support. |
| 9445 | Warning | Fan 4 failed. | Contact VDURA Technical Support. |
| 9446 | Warning | Fan 4 speed too slow. | Contact VDURA Technical Support. |
| 9450 | Warning | Fan 5 failed. | Contact VDURA Technical Support. |
| 9451 | Warning | Fan 5 speed too slow. | Contact VDURA Technical Support. |
| 9455 | Warning | Fan 6 failed. | Contact VDURA Technical Support. |
| 9456 | Warning | Fan 6 speed too slow. | Contact VDURA Technical Support. |
| 9460 | Warning | Fan 7 failed. | Contact VDURA Technical Support. |
| 9461 | Warning | Fan 7 speed too slow. | Contact VDURA Technical Support. |
| 9470 | Warning | Fibre channel card in port 1 failed. | Contact VDURA Technical Support. |
| 9471 | Warning | Fibre channel port 1 link is slow. | Check cabling and SFP+ modules. |
| 9472 | Warning | Fibre channel port 1 link is down. | Check cabling and SFP+ modules. |
| 9473 | Warning | Fibre channel card in port 2 failed. | Contact VDURA Technical Support. |
| 9474 | Warning | Fibre channel port 2 link is slow. | Check cabling and SFP+ modules. |
| 9475 | Warning | Fibre channel port 2 link is down. | Check cabling and SFP+ modules. |
| 9500 | Critical | Node Disk 2 encountered disk errors, contact Panasas Technical Support. | Contact VDURA Technical Support. |
| 9501 | Warning | Node disk 2 SMART predicted failure. | Contact VDURA Technical Support. |
| 9502 | Warning | Node disk 2 is an unsupported version. | Contact VDURA Technical Support. |
| 9503 | Warning | Node disk 2 is missing from the node. | Contact VDURA Technical Support. |
| 9504 | Warning | SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 9505 | Warning | SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 9506 | Info | The hardware serial of node has changed. | No specific user action is required. |
| 9600 | Warning | Battery Fan Module 1 failed: Fan Module 1 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 1 is on the left when looking down on the mother board of battery module from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9601 | Warning | Battery Fan Module 2 failed: Fan Module 2 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 2 is in the middle when looking down on the mother board of battery module from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9602 | Warning | Battery Fan Module 3 failed: Fan Module 3 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 3 is on the right when looking down on the mother board of battery module from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9603 | Warning | Battery Fan Module 1 not found: Fan Module 1 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 1 is on the left when looking down on the mother board of battery module from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9604 | Warning | Battery Fan Module 2 not found: Fan Module 2 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 2 is in the middle when looking down on the mother board of battery module from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9605 | Warning | Battery Fan Module 3 not found: Fan Module 3 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 3 is on the right when looking down on the mother board of battery module from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9609 | Warning | Node Fan Module 1 failed: Fan Module 1 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 1 is on the left when looking down on the mother board of node from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9610 | Warning | Node Fan Module 2 failed: Fan Module 2 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 2 is in the middle when looking down on the mother board of node from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9611 | Warning | Node Fan Module 3 failed: Fan Module 3 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 3 is on the right when looking down on the mother board of node from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9612 | Warning | Node Fan Module 1 not found: Fan Module 1 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 1 is on the left when looking down on the mother board of node from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9613 | Warning | Node Fan Module 2 not found: Fan Module 2 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 2 is in the middle when looking down on the mother board of node from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9614 | Warning | Node Fan Module 3 not found: Fan Module 3 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 3 is on the right when looking down on the mother board of node from the rear of the enclosure. | Contact VDURA Technical Support. |
| 9624 | Warning | Node’s metadata filesystem capacity is nearly full: %%PERCENTFULL%%% of metadata filesystem space has been used. | Delete data or add additional storage. |
| 9625 | Critical | Node’s metadata filesystem space has reached 100% of capacity. No additional data can be written to the node. | Delete data or add additional storage. |
| 9626 | Info | Node metadata filesystem is no longer full: Node’s metadata filesystem reached %%PERCENTFULL%%% of capacity. | No specific user action is required. |
| 9627 | Warning | StorageSet metadata filesystem capacity is nearly full: %%PERCENTFULL%%% of metadata filesystem space in StorageSet %%SETNAME%% has been used. | Contact VDURA Technical Support. |
| 9628 | Critical | StorageSet %%SETNAME%% is at 100% metadata filesystem capacity. No additional data can be written to the StorageSet %%SETNAME%%. | Contact VDURA Technical Support. |
| 9629 | Info | StorageSet metadata filesystem capacity is no longer full: StorageSet %%SETNAME%% metadata filesystem reached %%PERCENTFULL%%% of capacity. | No specific user action is required. |
| 9630 | Warning | KMIP server 1 (%%KMIP_ADDR%%) failed: %%RC%% | Contact VDURA Technical Support. |
| 9631 | Warning | KMIP server 2 (%%KMIP_ADDR%%) failed: %%RC%% | Contact VDURA Technical Support. |
| 9640 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9641 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9642 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9643 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9644 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9645 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9646 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9647 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9648 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9649 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9650 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9651 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9652 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9653 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9654 | Critical | Failed to unlock %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9655 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9656 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9657 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9658 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9659 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9660 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9661 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9662 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9663 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9664 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9665 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9666 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9667 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9668 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9669 | Warning | Failed to configure %%DRIVE%% drive: %%RC%% | Contact VDURA Technical Support. |
| 9870 | Warning | Client certificate for KMIP 1 will soon expire. | Update the client certificate for KMIP 1 until the expiration date. |
| 9871 | Warning | Root certificate for KMIP 1 will soon expire. | Update the client certificate for KMIP 1 until the expiration date. |
| 9872 | Warning | Client certificate for KMIP 2 will soon expire. | Update the client certificate for KMIP 2 until the expiration date. |
| 9873 | Warning | Root certificate for KMIP 2 will soon expire. | Update the root certificate for KMIP 2 until the expiration date. |
| 9874 | Critical | Client certificate for KMIP 1 expired. | Update the client certificate. |
| 9875 | Critical | Root certificate for KMIP 1 expired. | Update the root certificate. |
| 9876 | Critical | Client certificate for KMIP 2 expired. | Update the client certificate. |
| 9877 | Critical | Root certificate for KMIP 2 expired. | Update the root certificate. |
| 9902 | Critical | PAN_MGMT_EV_NODE_DRIVES_MISMATCH | Place drives into proper location. |
| 9903 | Warning | PAN_MGMT_EV_NODE_DRIVES_UNEXPECTED | Place drives into proper location. |
| 10000 | Warning | Power supply 3 failed (power supply module serial %%SERIAL%%). %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 10001 | Warning | Power supply 3 unsupported version. %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 10002 | Warning | Power supply 3 not found in enclosure with serial %%SHELFID%%. %%DESCRIPTION%% | Check if power supply module 3 is inserted properly. |
| 10003 | Critical | Power supply 3 over maximum temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Ambient temperature is too high. Adjust room temperature. |
| 10004 | Warning | Power supply 3 temperature high (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Ambient temperature is too high. Adjust room temperature. |
| 10005 | Info | Power supply 3 under temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Ambient temperature is too low. Adjust room temperature. |
| 10006 | Warning | Power supply 3, AC power fail: AC power disconnected from power supply module 3 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Check that power supply module is plugged in. |
| 10007 | Warning | Power supply 3 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 10008 | Warning | A 950W power supply module was replaced with an 800W power supply module 3 (enclosure serial %%SHELFID%%). This scenario can cause damage to the 800W power supply module. %%DESCRIPTION%% | Insert a 950W power supply module into this location. |
| 10100 | Warning | Power supply 4 failed (power supply module serial %%SERIAL%%). %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 10101 | Warning | Power supply 4 unsupported version. %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 10102 | Warning | Power supply 4 not found in enclosure with serial %%SHELFID%%. %%DESCRIPTION%% | Check if power supply module 4 is inserted properly. |
| 10103 | Critical | Power supply 4 over maximum temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Ambient temperature is too high. Adjust room temperature. |
| 10104 | Warning | Power supply 4 temperature high (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Ambient temperature is too high. Adjust room temperature. |
| 10105 | Info | Power supply 4 under temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Ambient temperature is too low. Adjust room temperature. |
| 10106 | Warning | Power supply 4, AC power fail: AC power disconnected from power supply module 4 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% | Check that power supply module is plugged in. |
| 10107 | Warning | Power supply 4 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% | Contact VDURA Technical Support. |
| 10108 | Warning | A 950W power supply module was replaced with an 800W power supply module 4 (enclosure serial %%SHELFID%%). This scenario can cause damage to the 800W power supply module. %%DESCRIPTION%% | Insert a 950W power supply module into this location. |
| 10902 | Warning | Power supply 3 fan failed: enclosure fan has failed in power supply module 3 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). Power supply 3 is on bottom left when looking at rear of enclosure. | Contact VDURA Technical Support. |
| 10903 | Warning | Power supply 4 fan failed: enclosure fan has failed in power supply module 4 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). Power supply 4 is on top left when looking at rear of enclosure. | Contact VDURA Technical Support. |
| 12000 | Warning | Node disk 3 encountered disk errors. | Contact VDURA Technical Support. |
| 12001 | Warning | Node disk 3 SMART predicted failure. | Contact VDURA Technical Support. |
| 12002 | Warning | Node disk 3 is an unsupported version. | Contact VDURA Technical Support. |
| 12003 | Warning | Node disk 3 is missing from the node. | Contact VDURA Technical Support. |
| 12004 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12005 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12006 | Info | Node disk 3 is rebuilding to mirror disk 1. | No specific user action is required. |
| 12200 | Info | Node disk 1 is rebuilding to mirror disk 0. | No specific user action is required. |
| 12020 | Warning | Node disk 4 encountered disk errors. | Contact VDURA Technical Support. |
| 12021 | Warning | Node disk 4 SMART predicted failure. | Contact VDURA Technical Support. |
| 12022 | Warning | Node disk 4 is an unsupported version. | Contact VDURA Technical Support. |
| 12023 | Warning | Node disk 4 is missing from the node. | Contact VDURA Technical Support. |
| 12024 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12025 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12026 | Info | Node disk 4 is rebuilding to mirror disk 1. | No specific user action is required. |
| 12040 | Warning | Node disk 5 encountered disk errors. | Contact VDURA Technical Support. |
| 12041 | Warning | Node disk 5 SMART predicted failure. | Contact VDURA Technical Support. |
| 12042 | Warning | Node disk 5 is an unsupported version. | Contact VDURA Technical Support. |
| 12043 | Warning | Node disk 5 is missing from the node. | Contact VDURA Technical Support. |
| 12044 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12045 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12046 | Info | Node disk 5 is rebuilding to mirror disk 1. | No specific user action is required. |
| 12060 | Warning | Node disk 6 encountered disk errors. | Contact VDURA Technical Support. |
| 12061 | Warning | Node disk 6 SMART predicted failure. | Contact VDURA Technical Support. |
| 12062 | Warning | Node disk 6 is an unsupported version. | Contact VDURA Technical Support. |
| 12063 | Warning | Node disk 6 is missing from the node. | Contact VDURA Technical Support. |
| 12064 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12065 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12066 | Info | Node disk 6 is rebuilding to mirror disk 1. | No specific user action is required. |
| 12080 | Warning | Node disk 7 encountered disk errors. | Contact VDURA Technical Support. |
| 12081 | Warning | Node disk 7 SMART predicted failure. | Contact VDURA Technical Support. |
| 12082 | Warning | Node disk 7 is an unsupported version. | Contact VDURA Technical Support. |
| 12083 | Warning | Node disk 7 is missing from the node. | Contact VDURA Technical Support. |
| 12084 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12085 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12086 | Info | Node disk 7 is rebuilding to mirror disk 1. | No specific user action is required. |
| 12100 | Warning | Node disk 8 encountered disk errors. | Contact VDURA Technical Support. |
| 12101 | Warning | Node disk 8 SMART predicted failure. | Contact VDURA Technical Support. |
| 12102 | Warning | Node disk 8 is an unsupported version. | Contact VDURA Technical Support. |
| 12103 | Warning | Node disk 8 is missing from the node. | Contact VDURA Technical Support. |
| 12104 | Warning | Node SSD wearout warning: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12105 | Warning | Node SSD available reserve space low: Drive is nearing failure. | Contact VDURA Technical Support. |
| 12106 | Info | Node disk 8 is rebuilding to mirror disk 1. | No specific user action is required. |
This guide documents Vantage as of version 12.0.0. Screen labels, tooltips, and available options may change slightly in later releases.