17. VDURA System Error Messages

This chapter provides a numerical list of VDURA system error messages.

Error messages are categorized as follows:

Category Description
Info Error recovery messages or configuration changes are typically logged to the Events page (see 5.2 Events Panel).
Warning Developing problems that might impair system availability or data integrity are logged to the Events page and emailed to system administrators.
Critical Problems that are an imminent risk to system availability or data integrity are logged to the Events page and emailed to system administrators.

The following table lists error messages and PanActive Manager error handling. %%SERIAL%%, %%SHELFID%%, and similar tokens are placeholders filled in with the actual serial number, shelf ID, or other identifying value at runtime.

Error Code Category Error Description Recommended Action
8405 Warning Power supply 1 failed: Power supply 1 has failed (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. Contact VDURA Technical Support.
8406 Warning Power supply 1 unsupported version: Power supply 1 is an unsupported version (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. Contact VDURA Technical Support.
8407 Critical Incompatible Power Supplies: Power supplies in shelf are incompatible (shelf serial %%SHELFID%%). This configuration is not supported. Contact VDURA Technical Support.
8408 Warning Power supply 1 not found: Power supply 1 is missing (shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. Check if power supply 1 is inserted properly.
8409 Critical Power supply 1 over maximum temperature: Power supply 1 temperature is above threshold (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. Ambient temperature is too high. Adjust room temperature.
8410 Warning Power supply 1 temperature high: Power supply 1 exceeds optimal temperature (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8411 Info Power supply 1 under temperature: Power supply 1 is under optimal temperature (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too low. Adjust room temperature.
8412 Warning Power supply 1, AC power fail: AC power disconnected from power supply 1 (PS1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. Check that power supply is plugged in.
8413 Warning Power supply 1 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% Contact VDURA Technical Support.
8414 Warning A 950W power supply was replaced with an 800W power supply in PS1 (shelf serial %%SHELFID%%). This scenario can cause damage to the 800W power supply. Insert a 950W power supply into this location.
8415 Warning Power supply 2 failed: Power supply 2 has failed (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. Contact VDURA Technical Support.
8416 Warning Power supply 2 unsupported version: Power supply 2 is an unsupported version (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. Contact VDURA Technical Support.
8417 Warning Node disk 9 encountered disk errors. Contact VDURA Technical Support.
8418 Warning Power supply 2 not found: Power supply 2 is missing (shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. Check if power supply 2 is inserted properly.
8419 Critical Power supply 2 over maximum temperature: Power supply 2 temperature is above threshold (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8420 Warning Power supply 2 temperature high: Power supply 2 exceeds optimal temperature (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8421 Info Power supply 2 temperature high: Power supply 2 exceeds optimal temperature (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient Temperature is too low. Adjust room temperature.
8422 Warning Power supply 2, AC power fail: AC power disconnected from power supply 2 (PS2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. Check that power supply is plugged in.
8423 Warning Power supply 2 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% Contact VDURA Technical Support.
8424 Warning A 950W power supply was replaced with an 800W power supply in PS2 (shelf serial %%SHELFID%%). This scenario can cause damage to the 800W power supply. Insert a 950 W power supply into this location.
8425 Critical Battery temperature over maximum: Shelf battery temperature is above critical threshold (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8426 Critical Battery failed: Shelf battery has failed (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8427 Warning Battery unsupported version: Shelf battery is an unsupported version (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8428 Warning Battery failure predicted: Shelf battery is predicted to fail (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8429 Critical Battery not found: Shelf battery is missing (shelf serial %%SHELFID%%). Check if battery module is inserted properly.
8430 Warning Battery temperature high: Shelf battery exceeds optimal temperature (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8431 Warning Battery low: Shelf battery charge is low (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Wait until fully charged. It can take up to 6 hours to fully charge battery. If the problem persists, contact VDURA Technical Support for further assistance regarding this message.
8432 Info Battery under temperature: Shelf battery is under optimal temperature (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too low. Adjust room temperature.
8433 Warning Node disk 10 encountered disk errors, contact VDURA Technical Support. Contact VDURA Technical Support.
8434 Warning Enclosure over power budget: The power draw of nodes exceeds the power supply capacity. Contact VDURA Technical Support for steps to bring the shelf within power budget.
8435 Critical Net Module 1 failed: Net Module 1 has failed (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8436 Warning Net Module 1 unsupported version: Net Module 1 is an unsupported version (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8437 Warning Node disk 11 encountered disk errors, contact VDURA Technical Support. Contact VDURA Technical Support.
8438 Critical Net Module 1 not found: Net Module 1 is missing (shelf serial %%SHELFID%%). Check if switch 1 is inserted properly.
8439 Warning Node disk 12 encountered disk errors, contact VDURA Technical Support. Contact VDURA Technical Support.
8440 Warning Net Module 1 checksum error: Checksum error on Device U6 (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8441 Warning Net Module 1 checksum error: Checksum error on Device U8 (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8442 Warning Node disk 13 encountered disk errors. Contact VDURA Technical Support.
8443 Critical Net Module 1 over maximum temperature: Switch 1 temperature is above threshold (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8444 Warning Net Module 1 temperature high: Net Module 1 exceeds optimal temperature (switch 1 serial %%SERIAL%%, shelf serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8445 Info Net Module 1 is under optimal temperature (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Ambient temperature is too low. Adjust room temperature.
8446 Warning Net Module 1 is resetting (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch management interface did not respond. Please wait 90 seconds for reset to complete.
8447 Warning Management interface of Net Module 1 is not responding (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch management interface is not responding. Please reset the switch when system is not busy and check that the switch firmware is up-to-date.
8448 Warning Net Module 1 firmware is out of date (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch firmware is out of date; upgrade is recommended. Contact VDURA Technical Support for further assistance.
8449 Warning Net Module 1 firmware is unsupported (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch firmware is not supported. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance.
8450 Critical Node is unavailable: Node is unavailable due to a software failure. Administrative action may be needed to reconstruct this node. Contact VDURA Technical Support to repair this node. If the node cannot be repaired, go to the Node Detail page and use the Reconstruct control to start reconstruction of data.
8451 Critical Node exceeds maximum temperature: Node temperature exceeds threshold. Shutdown is imminent. Adjust room temperature and check fans.
8452 Critical Node shutdown: Node has shutdown automatically due to critically high temperature. Adjust room temperature and check fans.
8453 Critical AC power failed: Shelf %%SHELFID%% is running on backup battery power. Shutdown is imminent. Go to the Hardware page and click the System Shutdown button.
8454 Warning Node disk nearly full: Node’s disk space that is available for user data has reached %%PERCENTFULL%%% of capacity. Add more storage to the StorageSet.
8455 Critical Node disk full: Node’s disk space that is available for user data has reached 100% of capacity. Add more storage to the StorageSet.
8456 Warning Node temperature high: Node exceeds optimal operating temperature. Ambient temperature is too high. Adjust room temperature.
8457 Warning Node memory errors: Number of memory errors in node are abnormally high. Contact VDURA Technical Support for a replacement node.
8458 Warning Node is now offline.
8459 Warning Node needs to be reinitialized: Node has unknown data on it and must be reinitialized to be used in this system. Contact VDURA Technical Support.
8460 Warning Node is unavailable. Node may be rebooting. Check for any network problems and be sure that the node is properly inserted in the slot.
8461 Warning OSD out of service: Reconstruction will begin on the volumes in the StorageSet. Wait until reconstruction completes on all volumes in the StorageSet and then replace the OSD.
8462 Warning No compatibility info for Net Module 1 firmware (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). There is no compatibility info for the switch firmware. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance.
8463 Critical Net Module 1 firmware is incompatible (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Upgrade switch firmware to a supported version. Contact VDURA Technical Support for further assistance.
8464 Warning Node disk 14 encountered disk errors, contact VDURA Technical Support. Contact VDURA Technical Support.
8465 Info Node removed: Node has been removed from the system. No specific user action is required.
8466 Info Node under temperature: Node is under optimal operating temperature. Ambient temperature is too low. Adjust room temperature.
8467 Info Node discovered by the system. No specific user action is required.
8468 Info Node is now online. No specific user action is required.
8469 Info Node has been moved from its previous enclosure and/or slot location. No specific user action is required.
8470 Info Node needs upgrade: Node software is inconsistent with system software. The system will automatically attempt to apply its software to this node. No action is needed.
8471 Info Node is performing a fsck. Wait until fsck completes.
8472 Warning Node unsupported version: Node hardware is not supported by current version of software (hardware serial %%BLADESERIAL%%, shelf serial %%SHELFID%%, slot %%SLOTID%%). Check that the hardware serial on this node is valid.
8473 Warning Node filesystem nearly full: The local filesystem %%FILESYSTEM%% on this node is %%PERCENTFULL%%% full.
8474 Info Node filesystem no longer full: The filesystem %%FILESYSTEM%% on node is %%PERCENTFULL%%% full. There is enough space now. No specific user action is required.
8475 Info Node disk no longer full: Node’s disk space that is available for user data has reached %%PERCENTFULL%%% of capacity. There is enough space now. No specific user action is required.
8476 Warning Node disk 9 SMART predicted failure. Contact VDURA Technical Support.
8477 Warning Node disk 10 SMART predicted failure. Contact VDURA Technical Support.
8480 Critical Node disk 0 encountered disk errors. Contact VDURA Technical Support.
8481 Warning Node disk 0 SMART predicted failure. Contact VDURA Technical Support.
8482 Warning Node disk 0 is an unsupported version. Contact VDURA Technical Support.
8483 Warning Node disk 0 is missing from the node. Contact VDURA Technical Support.
8484 Info Node disk 0 is rebuilding to mirror disk 1. No action is needed.
8485 Warning Net Module 1 firmware needs upgrade but upgrade firmware file not available (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch firmware is not supported. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance.
8486 Warning Net Module 1 firmware is newer than tested version (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Contact VDURA Technical Support to obtain the firmware file and for further assistance.
8487 Warning Net Module 1 detected uplink on a port that should not be an uplink (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Check that the enclosure switch is cabled correctly. Uplink should be sfp6, cx4, or lagg of ge.
8488 Warning Net Module 1 is not using trigger logic - potential performance problem (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). If the warning persists, contact VDURA Technical Support.
8489 Info Net Module 1 is experiencing packet flooding - performance may be reduced (switch 1 serial %%SERIAL%%, enclosure serial %%SHELFID%%). No specific user action is required.
8490 Critical Node disk 1 encountered disk errors. Contact VDURA Technical Support.
8491 Warning Node disk 1 SMART predicted failure. Contact VDURA Technical Support.
8492 Warning Node disk 1 is an unsupported version. Contact VDURA Technical Support.
8493 Warning Node disk 1 is missing from the node. Contact VDURA Technical Support.
8494 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8495 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8496 Info Node disk 1 is rebuilding to mirror disk 0. No specific user action is required.
8497 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8498 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8499 Warning Node disk 12 SMART predicted failure. Contact VDURA Technical Support.
8500 Warning Node disk 13 SMART predicted failure. Contact VDURA Technical Support.
8501 Info Storage added to StorageSet %%SETNAME%%. No specific user action is required.
8502 Info StorageSet affinity changed for shelf %%SHELFID%%. No specific user action is required.
8503 Critical StorageSet full: StorageSet %%SETNAME%% is at 100 % capacity, further writes or snapshots may not be allowed. Add more storage to the StorageSet.
8504 Warning Node disk 14 SMART predicted failure. Contact VDURA Technical Support.
8505 Warning Node disk 9 is an unsupported version. Contact VDURA Technical Support.
8506 Warning OSDs are not online in StorageSet %%SETNAME%%. See node and volume status for more details. Check node and volume status.
8507 Warning Node disk 10 is an unsupported version. Contact VDURA Technical Support.
8508 Warning StorageSet nearly full: %%PERCENTFULL%%% of space available to user in StorageSet %%SETNAME%% is full. Add more storage to the StorageSet.
8509 Critical StorageSet has no spare space: Reconstruction cannot be started on StorageSet %%SETNAME%% as there are no reserved OSDs in it. Add more storage to the StorageSet as soon as possible. Add more storage to the StorageSet.
8510 Info StorageSet created: StorageSet %%SETNAME%% is created. No specific user action is required.
8511 Info StorageSet deleted: StorageSet %%SETNAME%% is deleted. No specific user action is required.
8513 Info StorageSet capacity imbalance detected: The distribution of used space on OSDs in StorageSet %%SETNAME%% is not balanced. The system is working to rebalance the StorageSet automatically. Turn on capacity balancing for this StorageSet. If capacity balancing is already turned on, the system will automatically balance the distribution of used space in this StorageSet.
8515 Warning OSDv4 block allocation policy configuration is not consistent for all nodes in StorageSet %%SETNAME%%
8516 Warning StorageSet %%SETNAME%% uses OSDv4 block allocation policy that will be deprecated in the future releases
8517 Warning Node disk 11 is an unsupported version. Contact VDURA Technical Support.
8518 Warning Node disk 12 is an unsupported version. Contact VDURA Technical Support.
8519 Warning Node disk 13 is an unsupported version. Contact VDURA Technical Support.
8520 Warning Node disk 14 is an unsupported version. Contact VDURA Technical Support.
8521 Warning Volume degraded: One OSD is not responding. Performance on volume %%VOLNAME%% is degraded. Minimize accessing this volume for reads and writes. The performance of the system will be slower than expected. Reconstruction of data will start soon.
8522 Warning Volume offline: Volume %%VOLNAME%% has been taken offline-unavailable for administrative purpose.
8523 Critical Volume down: Volume %%VOLNAME%% is not accessible.
8524 Info Volume online: Volume %%VOLNAME%% has been brought online. No specific user action is required.
8525 Info Volume created: Volume %%VOLNAME%% has been created. No specific user action is required.
8526 Info Volume deleted: Volume %%VOLNAME%% has been deleted. No specific user action is required.
8527 Warning Volume has damaged files: Volume %%VOLNAME%% has damaged files. Contact VDURA Technical Support.
8528 Warning Volume offline: Volume %%VOLNAME%% has been taken offline for administrative purpose.
8529 Warning Inconsistent parity equation: Object %%OBJID%% (offset %%OFFSET%%, length %%LENGTH%%) has an inconsistent parity equation among its component objects.%%REPORTED_BY%%%%TRANSIENT% % Contact VDURA Technical Support.
8531 Info Volume %%VOLNAME%% has been set read- only. No specific user action is required.
8532 Warning Node disk 9 is missing from the node. Contact VDURA Technical Support.
8533 Info Volume background cleanup started: Background cleanup on the volume %%VOLNAME%% has begun. No specific user action is required.
8534 Info Volume background cleanup stopped: Background cleanup on the volume %%VOLNAME%% has stopped. No specific user action is required.
8535 Critical File System Recovery start: File System Recovery (FSRC) on the volume %%VOLNAME%% has begun. The system is checking and repairing the volume. During this process, the volume is offline.
8536 Warning File System Recovery recommended: File System Recovery (FSRC) recommended to repair inconsistencies in volume %%VOLNAME%%. The system has discovered an unexpected file system inconsistency. To repair inconsistencies, click the volume name, then start FSRC using the Recover Volume control. The volume will be offline while FSRC repairs it. Note that depending on the size of the volume, FSRC may take several hours to complete. Until the volume is repaired, some files or directories may be inaccessible.
8537 Info File System Recovery end: File System Recovery (FSRC) on the volume %%VOLNAME%% has completed. Fixed %%FIXED%% objects during recovery. The system has finished checking and repairing the volume. To examine any damaged files, click the volume name and follow the link to Damaged Files in Volume.
8538 Info Volume background cleanup completed: Background cleanup on the volume %%VOLNAME%% has completed. Reconstructed %%RECONED%% objects, removed %%REMOVED%% stale components. No specific user action is required.
8539 Critical Volume fault-tolerance exceeded: Volume %%VOLNAME%% has too many failed OSDs.
8540 Critical File System Recovery failed: File System Recovery (FSRC) on the volume %%VOLNAME%% failed to recover volume. Fixed %%FIXED%% objects, found %%FENCED%% damaged objects, and deleted %%DELETED%% objects during recovery. An error occurred while checking and repairing the volume. The system is unable to bring the volume online. To start FSRC again, click the volume name, then click the Recover Volume control. If FSRC is unable to complete, contact VDURA Technical Support for assistance.
8541 Critical File System Recovery failed: File System Recovery (FSRC) on the volume %%VOLNAME%% failed to recover volume. One or more data fragments have been removed from file system but are still occupying space in the system. Contact VDURA Technical Support for assistance to recover them.
8542 Info Volume reconstruction for drain: The system has started reconstructing data in volume %%VOLNAME%% to complete the drain process. Wait until volume comes back online.
8543 Info Volume rescue completed: Volume rescue on the volume %%VOLNAME%% has completed. Fixed %%FIXED%% objects, and deleted %%DELETED%% objects during rescue. The system has finished rescuing the volume. Run PanCLI volume rescue report in service mode to download a detailed report.
8544 Warning Node disk 10 is missing from the node. Contact VDURA Technical Support.
8545 Warning Node disk 11 is missing from the node. Contact VDURA Technical Support.
8546 Warning Node disk 12 is missing from the node. Contact VDURA Technical Support.
8547 Warning Node disk 13 is missing from the node. Contact VDURA Technical Support.
8548 Warning Node disk 14 is missing from the node. Contact VDURA Technical Support.
8549 Info Volume reconstruction stop: reconstruction of data in volume %%VOLNAME%% has stopped due to configuration or state changes. Check node and volume status for more details.
8550 Warning StorageSet has no spare space: StorageSet %%SETNAME%% has requested %%NUMDESIRED%% spare storage nodes but currently has no spares. This will not have any effect upon reconstruction of data that may be in progress, but the system will not be able to reconstruct or drain any additional storage nodes until another storage node is added. Add more storage to the StorageSet.
8551 Critical StorageSet spare failure: StorageSet %%SETNAME%% does not have enough space to reserve space for reconstruction. Requested %%NUMDESIRED%% MB but only reserved %%NUMRESERVED%% MB.
8552 Warning Volume reconstruction began: Reconstruction of data in volume %%VOLNAME%% began. Wait until reconstruction completes.
8553 Critical Reconstruction failed: Encountered error during reconstruction of data in volume %%VOLNAME%%. Contact VDURA Technical Support.
8554 Info Volume reconstruction complete: Reconstruction of data in volume %%VOLNAME%% is complete. No specific user action is required.
8555 Info StorageSet spare success: Successfully reserved requested space of %%NUMDESIRED%% MB in StorageSet %%SETNAME%%. No specific user action is required.
8556 Critical Volume reconstruction failed: some objects could not be reconstructed. Contact VDURA Technical Support.
8557 Critical Reconstruction failed: There was not enough space or not enough storage nodes to complete reconstruction in volume %%VOLNAME%%. Add more storage to the StorageSet. Add more storage to the StorageSet.
8558 Info StorageSet spare success: StorageSet %%SETNAME%% contains %%NUMDESIRED%% spare storage nodes for reconstruction. No specific user action is required.
8559 Critical Volume rescue reconstruction began: rescue reconstruction of data in volume %%VOLNAME%% began. Wait until rescue reconstruction completes.
8560 Critical Hard Quota Violation: Hard quota limit reached on volume %%VOLNAME%%. No further writes allowed in this volume. Try one or more of the following:
• Increase hard quota for the volume.
• Delete unneeded files from the volume. Note that in an environment with snapshots, deleting files may not actually free space.
• Delete the oldest snapshot and verify that enough space is available from the Storage tab.
• Add more storage to the StorageSet.
8561 Warning Soft Quota Violation: Soft quota limit reached on volume %%VOLNAME%%. Try one or more of the following:
• Increase soft quota for the volume.
• Delete unneeded files from the volume. Note that in an environment with snapshots, deleting files may not actually free space.
• Delete the oldest snapshot and verify that enough space is available from the Storage tab.
• Add more storage to the StorageSet.
8564 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8566 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8567 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8568 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8571 Warning Software - Unexpected result: System software encountered unexpected behavior in module %%CODEMODULE%%: %%MESSAGE%%. (version %%VERSION%%, %%FILENAME%%:%%LINENUMBER%%)
8572 Info Software Process Failed: The process %%MODULENAME%% has failed with exit code %%EXITCODE%% and will be restarted. The system has restarted this application automatically, so no action is needed. If you see many such messages, please report a bug with VDURA Technical Support.
8573 Info Software Process Restarts: The process %%MODULENAME%% exited with status %%EXITCODE%% and will be restarted. The system has restarted this application automatically, so no action is needed. If you see many such messages, please report a bug with VDURA Technical Support.
8574 Info DHCP Leases Low: A node failed to join the system as there are no IP Addresses available. Increase the range of IP Addresses. Add more IP addresses to address range. Go to the Network page and select the IP Ranges page to make changes.
8575 Info System online: The system is now online. No specific user action is required.
8576 Info System going offline-unavailable: The system is being brought offline. Data services will be turned off. No specific user action is required.
8577 Warning System offline-unavailable: Data services off.
8578 Info System rebooting: System is preparing for a reboot. No specific user action is required.
8579 Info System power down: System is powering down due to a failed node. No specific user action is required.
8580 Warning System is locked for new nodes: A new node was not allowed to join the system as the system is locked. To let the node join, go to the Hardware page and unlock the system. If the new node is intended for a different system on this subnet, no action is required.
8581 Warning IP address %%IP%% appears to be in use by a machine that is not part of this storage cluster. To fix this problem, either edit the system IP ranges not to include any IPs that are taken by machines outside of your system or change the outside machine to use an IP address that is outside of the system’s reserved IP ranges.
8582 Warning DirectFlow Client with IP Address %%IPADDR%% clock skew of %%CLOCKSKEW%% seconds exceeds %%MAXCLOCKSKEW%% second limit
8583 Warning System reboot failed.
8584 Warning System power down failed.
8585 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8586 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8587 Info Generic informational message. This is an informational message. No action is needed.
8588 Warning Node has a warning condition the cause of which is either a kernel crash or unknown. No specific user action is required. Contact VDURA Technical Support if the event reported causes any malfunction.
8589 Critical Node is in error condition the cause of which is unknown. No specific user action is required. Contact VDURA Technical Support if the event reported causes any malfunction.
8590 Info Syslog warning: slow syncs seen by iopathv4 No specific user action is required.
8591 Info If the drift increases to 10,000 milliseconds, DirectFlow clients will degrade to read-only mode. This is an informational message. However, it does suggest that the node generating the message is having problems contacting time servers or with its clock.
8592 Warning This will cause DirectFlow clients to degrade to read-only mode. Clock drift can be caused by loss of contact with your external time sources.
8593 Info If the drift increases to 10,000 milliseconds, it may cause volumes on the StorageSet that this node is a part of to become inaccessible. Clock drift can be caused by loss of contact with your external time sources.
8594 Warning This will cause volumes on the StorageSet that this node is a part of to become temporarily inaccessible. Clock drift can be caused by loss of contact with the realm president or local hardware or software failures.
8595 Info ntpd monitor: Clock skew from time server %%IP%% of %%NUMMS%% milliseconds has dropped below the threshold of %%NUMMSTHRESHOLD%% milliseconds. No action is needed. The time skew between the external time source and the node is improving.
8596 Warning If this continues, DirectFlow clients will degrade to read-only mode. Entering local clock sync can be caused by loss of contact with the time servers configured. You can use tools like ntptrace and ping to diagnose and rectify them.
8597 Warning If this situation persists, this node’s clock may drift from the clocks on the system, this node may go offline. Please check to see that this node re-synchronizes within the hour. Nodes going into local time sync like this can be caused by loss of contact with the realm president or local hardware or software failures.
8598 Info This event relates to being in local sync. No action is needed. Whatever caused nodes to move to local sync has been rectified.
8599 Info Timeout after 1 hour+10 min, as syslog_watcher will wait for 1 hour before sending a repeat message. Collect the /var/log/ security file from this host to check the origin of failed login attempts.
8602 Warning Failed to send email via SMTP server %%SMTPSERVER%% to %%EMAILADDRESSES%% with subject %%SUBJECT%%: %%MESSAGE%%. Check the connectivity to SMTP server as well as SMTP server security settings.
8603 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8604 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8605 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8606 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8607 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8608 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8609 Info Node disk 9 is rebuilding to mirror disk 1. No specific user action is required.
8610 Info Node disk 10 is rebuilding to mirror disk 1. No specific user action is required.
8612 Info Node disk 11 is rebuilding to mirror disk 1. No specific user action is required.
8613 Info Node disk 12 is rebuilding to mirror disk 1. No specific user action is required.
8614 Info Node disk 13 is rebuilding to mirror disk 1. No specific user action is required.
8615 Info Node disk 14 is rebuilding to mirror disk 1. No specific user action is required.
8620 Info Upgrading message. No specific user action is required.
8621 Info Upgrading message. No specific user action is required.
8622 Info Upgrading message. No specific user action is required.
8623 Info Upgrading message. No specific user action is required.
8624 Info Upgrading message. No specific user action is required.
8625 Critical Upgrading message.
8626 Info Upgrading message. No specific user action is required.
8627 Critical Upgrading message.
8628 Critical Upgrading message.
8629 Critical Upgrading message.
8630 Critical Upgrading message.
8631 Critical Upgrading message.
8632 Critical Upgrading message.
8633 Info Upgrading message. No specific user action is required.
8634 Critical Upgrading message.
8635 Warning Upgrading message.
8636 Info Upgrading message. No specific user action is required.
8637 Info Upgrading message No specific user action is required.
8638 Info Upgrading message. No specific user action is required.
8639 Info Upgrading message. No specific user action is required.
8640 Info Upgrading message. No specific user action is required.
8641 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
8642 Critical Node disk %%DRIVENUMBER%% encountered disk errors. Contact VDURA Technical Support.
8643 Warning Node disk %%DRIVENUMBER%% SMART predicted failure. Contact VDURA Technical Support.
8644 Warning Node disk %%DRIVENUMBER%% is missing from the node. Contact VDURA Technical Support.
8645 Warning Node disk %%DRIVENUMBER%% is an unsupported version. Contact VDURA Technical Support.
8646 Info Node disk %%DRIVENUMBER%% is rebuilding to mirror disk 1. No specific user action is required.
8647 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
8650 Info System is coming up. Wait a few minutes.
8651 Info Initial system startup has completed. Check the health of the system.
8652 Info Volume service moved: Service %%SERVICEID%% moved from Director %%FROMHWSERIAL%% to Director %%TOHWSERIAL%%. No specific user action is required.
8653 Warning Volume service moved leaving no backup: Service %%SERVICEID%% moved from Director %%FROMHWSERIAL%% to Director %%TOHWSERIAL%%. To ensure the volume service gets a backup location, make sure all directors are online.
8654 Info Volume service backup enabled: Service %%SERVICEID%% now has backup Director %%TOHWSERIAL%%. No specific user action is required.
8655 Warning Volume service backup disabled: Service %%SERVICEID%% does not have a backup. To ensure the volume service gets a backup location, make sure all directors are online.
8656 Info System going offline: The system is being brought offline. Data services will be turned off. No specific user action is required.
8657 Warning System offline: Data services off.
8658 Info System going offline for upgrade: The system is being brought offline for upgrade. Data services will be turned off. No specific user action is required.
8659 Warning System offline for upgrade: Data services off.
8661 Info Alias %%IP_ALIAS%% has been assigned. No specific user action is required.
8662 Warning Alias %%IP_ALIAS%% cannot be assigned: %%MESSAGE%% Check the status of all directors and validate IP alias configuration.
8663 Info Volume service removed: Service %%SERVICEID%% manages no volumes and has been removed. No specific user action is required.
8664 Warning Detected too many recent login failures. Check event log for details about failures on individual hosts. Collect the /var/log/ security file from affected hosts to check the origin of failed login attempts.
8665 Warning Detected one or more AWOL clients. Check event log for client details. Check the health of the clients reported as AWOL.
8670 Warning This battery module is nearing the end of its useful 3.5 year life. The battery module can continue to be used but should be replaced as soon as reasonably possible. Please open a Service Request with a list of battery hardware serial numbers impacted. The VDURA battery module is a consumable item but may be covered under the service entitlement you have purchased for this enclosure.
8684 Critical Node’s Small File Filesystem has reached 90% or more of capacity. Delete data or add additional storage.
8685 Warning Node’s Small File Filesystem capacity is more than 80% full. Delete data or add additional storage.
8686 Info Node’s Small File Filesystem has reached 50% or more of capacity. No specific user action is required.
8687 Info Node’s Small File Filesystem is below 50% capacity. No specific user action is required.
8688 Critical Node’s Large File Filesystem has reached 90% or more of capacity. Delete data or add additional storage.
8689 Warning Node’s Large File Filesystem capacity is more than 80% full. Delete data or add additional storage.
8690 Info Node’s Large File Filesystem has reached 50% or more of capacity. No specific user action is required.
8691 Info Node’s Large File Filesystem is below 50% capacity. No specific user action is required.
8697 Critical Node’s Metadata Filesystem has reached 90% or more of capacity. Contact VDURA Technical Support.
8698 Warning Node’s Metadata Filesystem capacity is more than 70% full. Contact VDURA Technical Support.
8699 Info Node’s Metadata Filesystem has reached below 70% of capacity. No specific user action is required.
8800 Critical JBOD (JBOD serial number: %%SERIAL%%) failed Contact VDURA Technical Support.
8801 Critical JBOD (JBOD serial number: %%SERIAL%%) not found. Contact VDURA Technical Support.
8802 Warning JBOD %%SERIAL%% predicted failure. Contact VDURA Technical Support.
8803 Critical IO module %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed. Contact VDURA Technical Support.
8804 Critical IO module %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) not found. Contact VDURA Technical Support.
8805 Warning IO module %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) predicted failure. Contact VDURA Technical Support.
8806 Critical JBOD fan %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed. Contact VDURA Technical Support.
8807 Critical JBOD fan %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) not found. Contact VDURA Technical Support.
8808 Warning JBOD fan %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) predicted failure. Contact VDURA Technical Support.
8809 Critical JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed. Contact VDURA Technical Support.
8810 Critical JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) not found. Contact VDURA Technical Support.
8811 Warning JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) predicted failure. Contact VDURA Technical Support.
8812 Warning JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) failed during the monthly battery test. Contact VDURA Technical Support.
8813 Warning JBOD power supply %%INDEX%% (JBOD serial number %%JBOD_SERIAL%%) AC power fail. Contact VDURA Technical Support.
8900 Warning Power supply 1 fan failed: Enclosure fan has failed in power supply 1 (fan serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 1 is on right when looking at rear of shelf. Contact VDURA Technical Support.
8901 Warning Battery fan failed: Enclosure fan has failed in battery module (fan serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8902 Warning Power supply 2 fan failed: Enclosure fan has failed in power supply 2 (fan serial %%SERIAL%%, shelf serial %%SHELFID%%). Power supply 2 is on left when looking at rear of shelf. Contact VDURA Technical Support.
8903 Critical There are 2 or more fans failed or missing in the enclosure. System will shut down automatically in a few minutes if this condition is not cleared up. Contact VDURA Technical Support.
8950 Critical Net module 2 has failed (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Contact VDURA Technical Support.
8951 Warning Net Module 2 unsupported version (switch 2 serial, enclosure serial %%SHELFID%%). Contact VDURA Technical Support.
8952 Critical Net module 2 not found (enclosure serial %%SHELFID%%). Check if switch 2 is inserted properly.
8953 Critical Net module 2 over maximum temperature (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8954 Warning Net Module 2 exceeds optimal temperature (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Ambient temperature is too high. Adjust room temperature.
8955 Info Net Module 2 under optimal temperature (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Ambient temperature is too low. Adjust room temperature.
8956 Warning Net Module 2 checksum error: Checksum error on Device U6 (switch 2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8957 Warning Net Module 2 checksum error: Checksum error on Device U8 (switch 2 serial %%SERIAL%%, shelf serial %%SHELFID%%). Contact VDURA Technical Support.
8958 Warning Net Module 2 is resetting (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch management interface did not respond. Please wait 90 seconds for reset to complete.
8959 Warning Management interface of Net Module 2 is not responding (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch management interface is not responding. Please reset the switch when system is not busy and check that the switch firmware is up-to-date.
8960 Warning Net Module 2 firmware is out of date (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch firmware is out of date; upgrade is recommended. Contact VDURA Technical Support for further assistance.
8961 Warning Net Module 2 firmware is unsupported (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Switch firmware is not supported. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance.
8962 Warning No compatibility info for Net Module 2 firmware (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). There is no compatibility info for the switch firmware. Downgrading firmware to a supported version is recommended. Contact VDURA Technical Support for further assistance.
8963 Critical Net module 2 firmware is incompatible (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Upgrade switch firmware to a supported version. Contact VDURA Technical Support for further assistance.
8964 Warning Net Module 2 firmware needs upgrade but upgrade firmware file not available (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Contact VDURA Technical Support.
8965 Warning Net Module 2 firmware is newer than tested version (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Consider downgrading switch firmware to a supported version. Contact VDURA Technical Support for further assistance.
8966 Warning Net Module 2 detected uplink on a port that should not be an uplink (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). Check that the enclosure switch is cabled correctly. Uplink should be sfp6, cx4, or lagg of ge.
8968 Info Net Module 2 is experiencing packet flooding - performance may be reduced (switch 2 serial %%SERIAL%%, enclosure serial %%SHELFID%%). If the warning persists, contact VDURA Technical Support.
8975 Info Battery test started. Any change in LED pattern on this shelf can be safely ignored during the test. The test will take up to one minute (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). No specific user action is required.
8976 Info Battery test completed successfully (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). No specific user action is required.
8977 Critical Battery test failed: battery drained too quickly (battery serial %%SERIAL%%, shelf serial %%SHELFID%%).
8978 Info Transient error during Battery test: battery test aborted (battery serial %%SERIAL%%, shelf serial %%SHELFID%%). Battery test will automatically run again later.
9050 Warning Node low battery: Node is waiting for shelf battery to get charged.
9051 Info Node online fsck active: Online fsck is running on the node. No specific user action is required.
9052 Info Node online fsck inactive: Online fsck stopped running on the node. No specific user action is required.
9053 Info Node got address: Node assigned IP Address by the system. No specific user action is required.
9062 Info Node clock sync: Node is performing NTP clock synchronization. Wait up to 2 minutes for clock synchronization to complete. If clock synchronization lasts longer than 2 minutes, make sure at least one of the NTP servers is responding.
9063 Warning One or more of this node’s drives have failed. Contact VDURA Technical Support.
9064 Warning One or more of this node’s drives may be damaged. Contact VDURA Technical Support.
9065 Info The quality of this node’s drives cannot be determined at this time. The system will continue testing the drives until a determination can be made. No action is needed.
9066 Info Tests for this node’s drives have passed. No specific user action is required.
9067 Info Node not ready to serve data: No active object storage service. No specific user action is required.
9068 Info Hardware activated. No specific user action is required.
9069 Info Performing secure erase. No specific user action is required.
9070 Info Hardware is booting. No specific user action is required.
9071 Info Hardware is shutting down. No specific user action is required.
9072 Info Timeout after 1 hour+10 min, as syslog_watcher will wait for 1 hour before sending a repeat message. Check the health of this client.
9073 Warning Found %%NUMECC%% ECC errors in the past %%TIMEPERIOD%%. Node may need to be drained or replaced depending on severity of ECC correctable error rate.
9074 Warning Found %%NUMERR%% %%ERRTYPE%% errors on drive %%DRIVENAME%%. Node may need to be drained or replaced depending on severity of ATA sector error rate.
9075 Warning Node is degraded: Controller is reconstructing this OSD. Contact VDURA Technical Support.
9079 Warning %%NUMERR%% IPS communication timeout errors occurred to OSD %%IP%% in the past %%TIMEPERIOD%%. Collect logs for the OSD and contact VDURA Technical Support.
9080 Info Hardware deactivated No specific user action is required.
9081 Info Node not ready to serve data: Network error. No specific user action is required.
9082 Info Node not ready to serve data: Polling/DB state is not reconciled. No specific user action is required.
9083 Info Node not ready to serve data: Configuration is not valid. No specific user action is required.
9100 Info OSD has successfully drained.
9101 Info OSD drain status: %%BYTES_REMAINING%% bytes (in %%OBJECTS_REMAINING%% objects) out of %%TOTAL_BYTES%% (and %%TOTAL_OBJECTS%% objects) still need to be drained. Check the drain status on the OSD Detail page to see whether drain is blocked.
9102 Warning Configuration message. Correct the NIS configuration.
9103 Info Configuration message. No specific user action is required.
9104 Warning Configuration message. Make sure the NIS servers is responding.
9105 Info Configuration message. No specific user action is required.
9120 Warning Lost connection to LDAP service could not be reestablished. Check the LDAP server connectivity. To retry, disable and re- enable LDAP. Also make sure that LDAP is in the Name Resolution Order list.
9122 Warning Connection to LDAP service reestablished.
9126 Warning Lost connection to NIS service could not be reestablished. Check the NIS server connectivity. To retry, disable and re- enable NIS User/Group Name Resolution. Also make sure that NIS is in the Name Resolution Order list.
9127 Warning Connection to NIS service reestablished.
9150 Info User Quota Violation Hard (bytes): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. No further writes allowed for this %%QUOTATYPE%% in this volume unless it has at most %%QUOTATHRSHLD%% of data. Increase hard quota bytes limit. Delete unneeded files from volume to keep usage below limit.
9151 Info User Quota Violation Soft (bytes): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. Increase soft quota bytes limit. Delete unneeded files from volume to keep usage below limit.
9152 Info User Quota Violation Hard (files): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. No further file creates allowed for this %%QUOTATYPE%% in this volume. Increase hard quota file limit. Delete unneeded files from volume to keep usage below limit.
9153 Info User Quota Violation Soft (files): Limit reached on volume %%VOLNAME%% for %%QUOTATYPE%%: %%QUOTAIDNAME%% (Id: %%QUOTAID%%) Limit = %%QUOTALIMIT%%. Increase soft quota file limit. Delete unneeded files from volume to keep usage below limit.
9170 Info User quota usage calculation in progress for volume %%VOLNAME%%. Quota usage data may not be current.
9171 Info User quota usage calculation is pending for volume %%VOLNAME%%. Quota usage data may not be current. No specific user action is required.
9172 Info User quota usage calculation completed for volume %%VOLNAME%%. No specific user action is required.
9182 Warning Node NIC 1 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9183 Warning Node NIC 2 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9184 Warning Node NIC 3 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9185 Warning Node NIC 4 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9186 Warning Node NIC 5 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9187 Warning Node NIC 6 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9188 Warning Node NIC 7 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9189 Warning Node NIC 8 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9190 Warning Node NIC 9 failed: %%DESCRIPTION%% Contact VDURA Technical Support.
9202 Warning Node NIC 1 transmission error: %%DESCRIPTION%% Check cabling.
9203 Warning Node NIC 2 transmission error: %%DESCRIPTION%% Check cabling.
9204 Warning Node NIC 3 transmission error: %%DESCRIPTION%% Check cabling.
9205 Warning Node NIC 4 transmission error: %%DESCRIPTION%% Check cabling.
9206 Warning Node NIC 5 transmission error: %%DESCRIPTION%% Check cabling.
9207 Warning Node NIC 6 transmission error: %%DESCRIPTION%% Check cabling.
9208 Warning Node NIC 7 transmission error: %%DESCRIPTION%% Check cabling.
9209 Warning Node NIC 8 transmission error: %%DESCRIPTION%% Check cabling.
9210 Warning Node NIC 9 transmission error: %%DESCRIPTION%% Check cabling.
9222 Warning Node NIC 1 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9223 Warning Node NIC 2 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9224 Warning Node NIC 3 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9225 Warning Node NIC 4 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9226 Warning Node NIC 5 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9227 Warning Node NIC 6 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9228 Warning Node NIC 7 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9229 Warning Node NIC 8 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9230 Warning Node NIC 9 slow transmission: %%DESCRIPTION%% Check 10 GE switch configuration.
9242 Warning Node NIC 1 not full duplex: %%DESCRIPTION%% Check switch configuration.
9243 Warning Node NIC 2 not full duplex: %%DESCRIPTION%% Check switch configuration.
9244 Warning Node NIC 3 not full duplex: %%DESCRIPTION%% Check switch configuration.
9245 Warning Node NIC 4 not full duplex: %%DESCRIPTION%% Check switch configuration.
9246 Warning Node NIC 5 not full duplex: %%DESCRIPTION%% Check switch configuration.
9247 Warning Node NIC 6 not full duplex: %%DESCRIPTION%% Check switch configuration.
9248 Warning Node NIC 7 not full duplex: %%DESCRIPTION%% Check switch configuration.
9249 Warning Node NIC 8 not full duplex: %%DESCRIPTION%% Check switch configuration.
9250 Warning Node NIC 9 not full duplex: %%DESCRIPTION%% Check switch configuration.
9262 Warning Node NIC 1 not active: %%DESCRIPTION%% Check cabling.
9263 Warning Node NIC 2 not active: %%DESCRIPTION%% Check cabling.
9264 Warning Node NIC 3 not active: %%DESCRIPTION%% Check cabling.
9265 Warning Node NIC 4 not active: %%DESCRIPTION%% Check cabling.
9266 Warning Node NIC 5 not active: %%DESCRIPTION%% Check cabling.
9267 Warning Node NIC 6 not active: %%DESCRIPTION%% Check cabling.
9268 Warning Node NIC 7 not active: %%DESCRIPTION%% Check cabling.
9269 Warning Node NIC 8 not active: %%DESCRIPTION%% Check cabling.
9270 Warning Node NIC 9 not active: %%DESCRIPTION%% Check cabling.
9282 Critical Node NIC 1 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9283 Critical Node NIC 2 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9284 Critical Node NIC 3 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9285 Critical Node NIC 4 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9286 Critical Node NIC 5 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9287 Critical Node NIC 6 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9288 Critical Node NIC 7 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9289 Critical Node NIC 8 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9290 Critical Node NIC 9 wrong broadcast address: %%DESCRIPTION%% Configure the broadcast address correctly.
9302 Warning Node NIC 1 not active: %%DESCRIPTION%% Try rebooting the node.
9303 Warning Node NIC 2 not in use: %%DESCRIPTION%% Try rebooting the node.
9304 Warning Node NIC 3 not in use: %%DESCRIPTION%% Try rebooting the node.
9305 Warning Node NIC 4 not in use: %%DESCRIPTION%% Try rebooting the node.
9306 Warning Node NIC 5 not in use: %%DESCRIPTION%% Try rebooting the node.
9307 Warning Node NIC 6 not in use: %%DESCRIPTION%% Try rebooting the node.
9308 Warning Node NIC 7 not in use: %%DESCRIPTION%% Try rebooting the node.
9309 Warning Node NIC 8 not in use: %%DESCRIPTION%% Try rebooting the node.
9310 Warning Node NIC 9 not in use: %%DESCRIPTION%% Try rebooting the node.
9322 Warning Node NIC 1 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9323 Warning Node NIC 2 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9324 Warning Node NIC 3 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9325 Warning Node NIC 4 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9326 Warning Node NIC 5 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9327 Warning Node NIC 6 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9328 Warning Node NIC 7 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9329 Warning Node NIC 8 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9330 Warning Node NIC 9 has no external connectivity: %%DESCRIPTION%% Check cable and switch configuration.
9362 Warning Node NIC 1 not in use: %%DESCRIPTION%% Try rebooting the node.
9363 Warning Node NIC 2 not in use: %%DESCRIPTION%% Try rebooting the node.
9364 Warning Node NIC 3 not in use: %%DESCRIPTION%% Try rebooting the node.
9365 Warning Node NIC 4 not in use: %%DESCRIPTION%% Try rebooting the node.
9366 Warning Node NIC 5 not in use: %%DESCRIPTION%% Try rebooting the node.
9367 Warning Node NIC 6 not in use: %%DESCRIPTION%% Try rebooting the node.
9368 Warning Node NIC 7 LACP not active: %%DESCRIPTION%% Check switch configuration.
9369 Warning Node NIC 8 LACP not active: %%DESCRIPTION%% Check switch configuration.
9370 Warning Node NIC 9 LACP not active: %%DESCRIPTION%% Check switch configuration.
9400 Warning Power supply 1 failed. Contact VDURA Technical Support.
9401 Warning Power supply 1 has unsupported version. Contact VDURA Technical Support.
9402 Warning Power supply 1 not found. Check whether power supply 1 is inserted properly.
9403 Warning Power supply 1 failure predicted. Contact VDURA Technical Support.
9404 Warning Power supply 1 AC power fail: AC power disconnected from power supply 1. Check that power supply 1 is plugged in.
9410 Warning Power supply 2 failed. Contact VDURA Technical Support.
9411 Warning Power supply 2 has unsupported version. Contact VDURA Technical Support.
9412 Warning Power supply 2 not found. Check whether power supply 2 is inserted properly.
9413 Warning Power supply 2 failure predicted. Contact VDURA Technical Support.
9414 Warning Power supply 2 AC power fail: AC power disconnected from power supply 2. Check that power supply 2 is plugged in.
9420 Warning IPMI card failed. Contact VDURA Technical Support.
9421 Warning IPMI card not responding correctly. Contact VDURA Technical Support.
9422 Warning IPMI card not found. Check whether IPMI card is inserted properly.
9423 Warning Non-volatile memory system failure is predicted. Contact VDURA Technical Support.
9424 Warning Non-volatile memory system has failed. Contact VDURA Technical Support.
9430 Warning Fan 1 failed. Contact VDURA Technical Support.
9431 Warning Fan 1 speed too slow. Contact VDURA Technical Support.
9435 Warning Fan 2 failed. Contact VDURA Technical Support.
9436 Warning Fan 2 speed too slow. Contact VDURA Technical Support.
9440 Warning Fan 3 failed. Contact VDURA Technical Support.
9441 Warning Fan 3 speed too slow. Contact VDURA Technical Support.
9445 Warning Fan 4 failed. Contact VDURA Technical Support.
9446 Warning Fan 4 speed too slow. Contact VDURA Technical Support.
9450 Warning Fan 5 failed. Contact VDURA Technical Support.
9451 Warning Fan 5 speed too slow. Contact VDURA Technical Support.
9455 Warning Fan 6 failed. Contact VDURA Technical Support.
9456 Warning Fan 6 speed too slow. Contact VDURA Technical Support.
9460 Warning Fan 7 failed. Contact VDURA Technical Support.
9461 Warning Fan 7 speed too slow. Contact VDURA Technical Support.
9470 Warning Fibre channel card in port 1 failed. Contact VDURA Technical Support.
9471 Warning Fibre channel port 1 link is slow. Check cabling and SFP+ modules.
9472 Warning Fibre channel port 1 link is down. Check cabling and SFP+ modules.
9473 Warning Fibre channel card in port 2 failed. Contact VDURA Technical Support.
9474 Warning Fibre channel port 2 link is slow. Check cabling and SFP+ modules.
9475 Warning Fibre channel port 2 link is down. Check cabling and SFP+ modules.
9500 Critical Node Disk 2 encountered disk errors, contact Panasas Technical Support. Contact VDURA Technical Support.
9501 Warning Node disk 2 SMART predicted failure. Contact VDURA Technical Support.
9502 Warning Node disk 2 is an unsupported version. Contact VDURA Technical Support.
9503 Warning Node disk 2 is missing from the node. Contact VDURA Technical Support.
9504 Warning SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
9505 Warning SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
9506 Info The hardware serial of node has changed. No specific user action is required.
9600 Warning Battery Fan Module 1 failed: Fan Module 1 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 1 is on the left when looking down on the mother board of battery module from the rear of the enclosure. Contact VDURA Technical Support.
9601 Warning Battery Fan Module 2 failed: Fan Module 2 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 2 is in the middle when looking down on the mother board of battery module from the rear of the enclosure. Contact VDURA Technical Support.
9602 Warning Battery Fan Module 3 failed: Fan Module 3 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 3 is on the right when looking down on the mother board of battery module from the rear of the enclosure. Contact VDURA Technical Support.
9603 Warning Battery Fan Module 1 not found: Fan Module 1 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 1 is on the left when looking down on the mother board of battery module from the rear of the enclosure. Contact VDURA Technical Support.
9604 Warning Battery Fan Module 2 not found: Fan Module 2 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 2 is in the middle when looking down on the mother board of battery module from the rear of the enclosure. Contact VDURA Technical Support.
9605 Warning Battery Fan Module 3 not found: Fan Module 3 of battery module serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 3 is on the right when looking down on the mother board of battery module from the rear of the enclosure. Contact VDURA Technical Support.
9609 Warning Node Fan Module 1 failed: Fan Module 1 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 1 is on the left when looking down on the mother board of node from the rear of the enclosure. Contact VDURA Technical Support.
9610 Warning Node Fan Module 2 failed: Fan Module 2 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 2 is in the middle when looking down on the mother board of node from the rear of the enclosure. Contact VDURA Technical Support.
9611 Warning Node Fan Module 3 failed: Fan Module 3 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% has failed. Fan Module 3 is on the right when looking down on the mother board of node from the rear of the enclosure. Contact VDURA Technical Support.
9612 Warning Node Fan Module 1 not found: Fan Module 1 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 1 is on the left when looking down on the mother board of node from the rear of the enclosure. Contact VDURA Technical Support.
9613 Warning Node Fan Module 2 not found: Fan Module 2 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 2 is in the middle when looking down on the mother board of node from the rear of the enclosure. Contact VDURA Technical Support.
9614 Warning Node Fan Module 3 not found: Fan Module 3 of node serial %%SERIAL%% in enclosure serial %%SHELFID%% not found. Fan Module 3 is on the right when looking down on the mother board of node from the rear of the enclosure. Contact VDURA Technical Support.
9624 Warning Node’s metadata filesystem capacity is nearly full: %%PERCENTFULL%%% of metadata filesystem space has been used. Delete data or add additional storage.
9625 Critical Node’s metadata filesystem space has reached 100% of capacity. No additional data can be written to the node. Delete data or add additional storage.
9626 Info Node metadata filesystem is no longer full: Node’s metadata filesystem reached %%PERCENTFULL%%% of capacity. No specific user action is required.
9627 Warning StorageSet metadata filesystem capacity is nearly full: %%PERCENTFULL%%% of metadata filesystem space in StorageSet %%SETNAME%% has been used. Contact VDURA Technical Support.
9628 Critical StorageSet %%SETNAME%% is at 100% metadata filesystem capacity. No additional data can be written to the StorageSet %%SETNAME%%. Contact VDURA Technical Support.
9629 Info StorageSet metadata filesystem capacity is no longer full: StorageSet %%SETNAME%% metadata filesystem reached %%PERCENTFULL%%% of capacity. No specific user action is required.
9630 Warning KMIP server 1 (%%KMIP_ADDR%%) failed: %%RC%% Contact VDURA Technical Support.
9631 Warning KMIP server 2 (%%KMIP_ADDR%%) failed: %%RC%% Contact VDURA Technical Support.
9640 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9641 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9642 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9643 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9644 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9645 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9646 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9647 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9648 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9649 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9650 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9651 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9652 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9653 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9654 Critical Failed to unlock %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9655 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9656 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9657 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9658 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9659 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9660 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9661 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9662 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9663 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9664 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9665 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9666 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9667 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9668 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9669 Warning Failed to configure %%DRIVE%% drive: %%RC%% Contact VDURA Technical Support.
9870 Warning Client certificate for KMIP 1 will soon expire. Update the client certificate for KMIP 1 until the expiration date.
9871 Warning Root certificate for KMIP 1 will soon expire. Update the client certificate for KMIP 1 until the expiration date.
9872 Warning Client certificate for KMIP 2 will soon expire. Update the client certificate for KMIP 2 until the expiration date.
9873 Warning Root certificate for KMIP 2 will soon expire. Update the root certificate for KMIP 2 until the expiration date.
9874 Critical Client certificate for KMIP 1 expired. Update the client certificate.
9875 Critical Root certificate for KMIP 1 expired. Update the root certificate.
9876 Critical Client certificate for KMIP 2 expired. Update the client certificate.
9877 Critical Root certificate for KMIP 2 expired. Update the root certificate.
9902 Critical PAN_MGMT_EV_NODE_DRIVES_MISMATCH Place drives into proper location.
9903 Warning PAN_MGMT_EV_NODE_DRIVES_UNEXPECTED Place drives into proper location.
10000 Warning Power supply 3 failed (power supply module serial %%SERIAL%%). %%DESCRIPTION%% Contact VDURA Technical Support.
10001 Warning Power supply 3 unsupported version. %%DESCRIPTION%% Contact VDURA Technical Support.
10002 Warning Power supply 3 not found in enclosure with serial %%SHELFID%%. %%DESCRIPTION%% Check if power supply module 3 is inserted properly.
10003 Critical Power supply 3 over maximum temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Ambient temperature is too high. Adjust room temperature.
10004 Warning Power supply 3 temperature high (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Ambient temperature is too high. Adjust room temperature.
10005 Info Power supply 3 under temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Ambient temperature is too low. Adjust room temperature.
10006 Warning Power supply 3, AC power fail: AC power disconnected from power supply module 3 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Check that power supply module is plugged in.
10007 Warning Power supply 3 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% Contact VDURA Technical Support.
10008 Warning A 950W power supply module was replaced with an 800W power supply module 3 (enclosure serial %%SHELFID%%). This scenario can cause damage to the 800W power supply module. %%DESCRIPTION%% Insert a 950W power supply module into this location.
10100 Warning Power supply 4 failed (power supply module serial %%SERIAL%%). %%DESCRIPTION%% Contact VDURA Technical Support.
10101 Warning Power supply 4 unsupported version. %%DESCRIPTION%% Contact VDURA Technical Support.
10102 Warning Power supply 4 not found in enclosure with serial %%SHELFID%%. %%DESCRIPTION%% Check if power supply module 4 is inserted properly.
10103 Critical Power supply 4 over maximum temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Ambient temperature is too high. Adjust room temperature.
10104 Warning Power supply 4 temperature high (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Ambient temperature is too high. Adjust room temperature.
10105 Info Power supply 4 under temperature (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Ambient temperature is too low. Adjust room temperature.
10106 Warning Power supply 4, AC power fail: AC power disconnected from power supply module 4 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). %%DESCRIPTION%% Check that power supply module is plugged in.
10107 Warning Power supply 4 failed during the monthly battery test (power supply module serial %%SERIAL%%). %%DESCRIPTION%% Contact VDURA Technical Support.
10108 Warning A 950W power supply module was replaced with an 800W power supply module 4 (enclosure serial %%SHELFID%%). This scenario can cause damage to the 800W power supply module. %%DESCRIPTION%% Insert a 950W power supply module into this location.
10902 Warning Power supply 3 fan failed: enclosure fan has failed in power supply module 3 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). Power supply 3 is on bottom left when looking at rear of enclosure. Contact VDURA Technical Support.
10903 Warning Power supply 4 fan failed: enclosure fan has failed in power supply module 4 (power supply module serial %%SERIAL%%, enclosure serial %%SHELFID%%). Power supply 4 is on top left when looking at rear of enclosure. Contact VDURA Technical Support.
12000 Warning Node disk 3 encountered disk errors. Contact VDURA Technical Support.
12001 Warning Node disk 3 SMART predicted failure. Contact VDURA Technical Support.
12002 Warning Node disk 3 is an unsupported version. Contact VDURA Technical Support.
12003 Warning Node disk 3 is missing from the node. Contact VDURA Technical Support.
12004 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
12005 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
12006 Info Node disk 3 is rebuilding to mirror disk 1. No specific user action is required.
12200 Info Node disk 1 is rebuilding to mirror disk 0. No specific user action is required.
12020 Warning Node disk 4 encountered disk errors. Contact VDURA Technical Support.
12021 Warning Node disk 4 SMART predicted failure. Contact VDURA Technical Support.
12022 Warning Node disk 4 is an unsupported version. Contact VDURA Technical Support.
12023 Warning Node disk 4 is missing from the node. Contact VDURA Technical Support.
12024 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
12025 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
12026 Info Node disk 4 is rebuilding to mirror disk 1. No specific user action is required.
12040 Warning Node disk 5 encountered disk errors. Contact VDURA Technical Support.
12041 Warning Node disk 5 SMART predicted failure. Contact VDURA Technical Support.
12042 Warning Node disk 5 is an unsupported version. Contact VDURA Technical Support.
12043 Warning Node disk 5 is missing from the node. Contact VDURA Technical Support.
12044 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
12045 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
12046 Info Node disk 5 is rebuilding to mirror disk 1. No specific user action is required.
12060 Warning Node disk 6 encountered disk errors. Contact VDURA Technical Support.
12061 Warning Node disk 6 SMART predicted failure. Contact VDURA Technical Support.
12062 Warning Node disk 6 is an unsupported version. Contact VDURA Technical Support.
12063 Warning Node disk 6 is missing from the node. Contact VDURA Technical Support.
12064 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
12065 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
12066 Info Node disk 6 is rebuilding to mirror disk 1. No specific user action is required.
12080 Warning Node disk 7 encountered disk errors. Contact VDURA Technical Support.
12081 Warning Node disk 7 SMART predicted failure. Contact VDURA Technical Support.
12082 Warning Node disk 7 is an unsupported version. Contact VDURA Technical Support.
12083 Warning Node disk 7 is missing from the node. Contact VDURA Technical Support.
12084 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
12085 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
12086 Info Node disk 7 is rebuilding to mirror disk 1. No specific user action is required.
12100 Warning Node disk 8 encountered disk errors. Contact VDURA Technical Support.
12101 Warning Node disk 8 SMART predicted failure. Contact VDURA Technical Support.
12102 Warning Node disk 8 is an unsupported version. Contact VDURA Technical Support.
12103 Warning Node disk 8 is missing from the node. Contact VDURA Technical Support.
12104 Warning Node SSD wearout warning: Drive is nearing failure. Contact VDURA Technical Support.
12105 Warning Node SSD available reserve space low: Drive is nearing failure. Contact VDURA Technical Support.
12106 Info Node disk 8 is rebuilding to mirror disk 1. No specific user action is required.

This guide documents Vantage as of version 12.0.0. Screen labels, tooltips, and available options may change slightly in later releases.